Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T01CM01888
Permit Details
Apply Date:
04/19/2001
Applicant:
U S HOME OF ARIZONA
Description:
SFR:TD#13-82-88
Contractors:
- U S HOME OF ARIZONA
Permit Reviews
Permit Number - T01CM01888
Permit Status: Final
Permit Description: SFR:TD#13-82-88
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/19/2001 | RESIDENTIAL BLDG/ZONING/FLOOD | 04/20/2001 | COMPLETED |
Completed Inspections
Permit Status: Final
Permit Number: T01CM01888
Permit Description: SFR:TD#13-82-88
Total Completed Inspections - 24
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/01/2001 | PLUMBING - SEWER HCS CONNECT | AQUIROZ | Approved | IVRS - Inspection 0000* |
05/01/2001 | PLUMBING - YARD WTR LINE/TEST | AQUIROZ | Approved | IVRS - Inspection 0000* |
05/01/2001 | PLUMBING - ROUGH, SOIL | AQUIROZ | Approved | IVRS - Inspection 0000* |
05/02/2001 | ELECTRIC - UFER | AQUIROZ | Approved | IVRS - Inspection 0000* |
05/02/2001 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection 0000* |
05/02/2001 | STEM WALL/RETAINING WALL | AQUIROZ | Approved | IVRS - Inspection 0000* |
05/02/2001 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection 0000* |
05/22/2001 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
05/22/2001 | EXT METAL CLIPS/EXT SHEATHING | AQUIROZ | Approved | IVRS - Inspection 0000* |
06/01/2001 | MECHANICAL - INTERMEDIATE | AQUIROZ | Approved | IVRS - Inspection 0000* |
06/01/2001 | PLUMBING - GAS PRESSURE TEST | AQUIROZ | Approved | IVRS - Inspection 0000* |
06/01/2001 | ELECTRIC - INTERMEDIATE | AQUIROZ | Approved | IVRS - Inspection 0000* |
06/06/2001 | ELECTRIC - TEMPORARY SERVICE | AQUIROZ | Approved | IVRS - Inspection 0000* |
06/06/2001 | ELECTRIC - CABLE DROP | AQUIROZ | Approved | IVRS - Inspection 0000* |
06/08/2001 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
06/08/2001 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection 0000* |
06/08/2001 | STUCCO MESH | AQUIROZ | Approved | IVRS - Inspection 0000* |
07/12/2001 | PERMIT FINALED | AQUIROZ | Approved | |
07/12/2001 | MECHANICAL - FINAL | AQUIROZ | Approved | IVRS - Inspection 0000* |
07/12/2001 | PLUMBING - FINAL | AQUIROZ | Approved | IVRS - Inspection 0000* |
07/12/2001 | PLUMBING - INTERMEDIATE | AQUIROZ | Approved | IVRS - Inspection 0000* |
07/12/2001 | ELECTRIC - FINAL | AQUIROZ | Approved | IVRS - Inspection 0000* |
07/12/2001 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection 0000* |
07/12/2001 | FRAMING | AQUIROZ | Approved | IVRS - Inspection 0000* |