Permit: T01CM01885
Permit Details
Status:
C of o
Type:
SINGLE FAMILY NEW
Address:
3120 W MOCKINGBIRD LN
Address NEW:
3120 W MOCKINGBIRD LN
Apply Date:
04/19/2001
Applicant:
RICHARD RINCON
Description:
NEW:SFR
Architects:
- AMY, NORMAN ARTHUR
Permit Reviews
Permit Number - T01CM01885
Permit Status: C of o
Permit Description: NEW:SFR
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/19/2001 | RESIDENTIAL BLDG/ZONING/FLOOD/WWM | 11/20/2001 | COMPLETED |
| 11/20/2001 | RESUBMITTAL | 11/28/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM01885
Permit Status: C of o
Permit Description: NEW:SFR
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/19/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM01885
Permit Description: NEW:SFR
Total Completed Inspections - 17
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/10/2002 | PLUMBING - ROUGH, SOIL | DBRITO | Approved | IVRS - Inspection 0000* |
| 03/15/2002 | ROOF NAILING | DBRITO | Approved | IVRS - Inspection 0000*/ 1) OK TO CONTINUE |
| 04/09/2002 | MECHANICAL - INTERMEDIATE | DBRITO | Approved | IVRS - Inspection 0999* |
| 04/09/2002 | PLUMBING - INTERMEDIATE | DBRITO | Approved | IVRS - Inspection 0999* |
| 04/09/2002 | ELECTRIC - INTERMEDIATE | DBRITO | Approved | IVRS - Inspection 0999* |
| 04/09/2002 | FRAMING | DBRITO | Approved | IVRS - Inspection 0999*/ 1) TRIMMERS MISSING AT DOORS 2) ELECTRIC NOT COMPLETE 3) SECURE BRG WALLS TO FLOOR WITH PINS OR ABS 4) TRAP REQUIRED TO BE SAME DIAMETER AS TRAP ARM 5) DRYER VENT NOT PER CODE 6) REMOVE WIRE MESH AT DRYER VENT T-TOP (FIRE HAZARD) |
| 04/24/2002 | SHEET ROCK NAILING | MTESTER | Approved | IVRS - Inspection 0000* |
| 07/26/2002 | ELECTRIC - CABLE DROP | DBRITO | Approved | IVRS - Inspection 0000* |
| 07/29/2002 | ELECTRIC - TEMPORARY SERVICE | DBRITO | Approved | IVRS - Inspection 0000* |
| 08/28/2002 | PERMIT FINALED | DBRITO | Approved | |
| 08/28/2002 | MECHANICAL - FINAL | DBRITO | Approved | IVRS - Inspection 0000* |
| 08/28/2002 | PLUMBING - FINAL | DBRITO | Approved | IVRS - Inspection 0000* |
| 08/28/2002 | PLUMBING - YARD WTR LINE/TEST | DBRITO | Approved | IVRS - Inspection 0000* |
| 08/28/2002 | ELECTRIC - FINAL | DBRITO | Approved | IVRS - Inspection 0000* |
| 08/28/2002 | ELECTRIC - UNDERGROUND | DBRITO | Approved | IVRS - Inspection 0000* |
| 08/28/2002 | BUILDING - FINAL | DBRITO | Approved | IVRS - Inspection 0000* |
| 08/28/2002 | U VALUE FOR WINDOW | DBRITO | Approved |