Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
03/30/2001
Applicant:
METRO PERMIT EXPRESS, INC
Description:
TI:OFFICE
Contractors:
  • CAYLOR CONSTRUCTION COMPANY , RO

Permit Reviews

Permit Number - T01CM01537
Permit Status: C of o
Permit Description: TI:OFFICE
Start Date Submittal Complete Date Status  
03/30/2001 COMMERCIAL TI 04/17/2001 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T01CM01537
Permit Status: C of o
Permit Description: TI:OFFICE
Total Outstanding Activity Conditions - 1
Date Name
03/30/2001 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T01CM01537
Permit Description: TI:OFFICE
Total Completed Inspections - 13
Date Description Inspector Results Comments
05/23/2001 PLUMBING - ROUGH, SOIL TRINIVJR Approved IVRS - Inspection 0000*1)SOIL WATER TEST OK.2)P.O.C. OF NEW BUILDING DRAIN TO EXISTING BUILDING DRAINS OK.3)NOTE:2" HORIZONIAL VENT FOR SINK ON WEST SIDE EXCEEDS MAX. ALLOWED DISTANCE OF HORIZONTIAL RUN.
05/30/2001 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection 0000*
05/30/2001 FRAMING AMATHIES Approved IVRS - Inspection 0000*
06/21/2001 PLUMBING - PROGRESS TRINIVJR Approved IVRS - Inspection 0000*
06/21/2001 PLUMBING - ABOVE CEILING TRINIVJR Approved IVRS - Inspection 0000*
06/21/2001 PLUMBING - INTERMEDIATE TRINIVJR Approved IVRS - Inspection 0000*1)SINK AT BREAK ROOM MUST HAVE C.O. WHERE IT CAN BE ACCESSIBLE.
DISHWASHER IS IN THE WAY.
06/21/2001 SHEET ROCK NAILING AMATHIES Approved IVRS - Inspection 0000*
06/29/2001 ELECTRIC - ABOVE CEILING DSANTACR Approved IVRS - Inspection 0000*
07/02/2001 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection 0000*
07/02/2001 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection 0000*REMOVE PLASTIC DRAIN LINE FROM AN LANDLER NO COMBRUSTIBLES ALLOW IN RETURN PLENUM. PIPE CANNOT TRAP WATER OK FOR CEILING TILES.
07/02/2001 PLUMBING - FINAL TRINIVJR Approved IVRS - Inspection 0000*1.) PLBG FINAL OK 2.) ALL CORRECTIONS HAVE BEEN MADE
07/06/2001 SIGN - FINAL JYBARRA Approved IVRS - Inspection 0000*
07/06/2001 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection 0000*

Documents

File Name Document Type  
C OF O_07-06-2001.TIF CERT OF OCC VIEW