| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/23/2001 | RESIDENTIAL BLDG/ZONING/FLOOD | 03/23/2001 | COMPLETED |
Outstanding Inspections
Permit Status: Expired
Permit Number: T01CM01441
Permite Description: SFR:TD#13-57-44
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/17/2001 | BUILDING - FINAL | N/A | Denied | IVRS - Inspection 0999*/ 1) PROVIDE ATMOSPHERE VACUMN BREAKER AT IRRIGATION LINES 2) BEAL PENETRATION IN GARAGE CEILING AT HOT WATER FLUE PIPE 3) LAUNDRY ROOM EXHAUST FAN NOT OPERABLE 4) BOMBER DOOR GARAGE TO HOUSE NOT SELF CLOSING 5) PROVIDE A LADDER FOR ATTIC INSPECITON 6) POST TENSION NOT STAMPED AT CENTER GARAGE NOT TAGGED AT YARD WATER |
Completed Inspections
Permit Status: Expired
Permit Number: T01CM01441
Permit Description: SFR:TD#13-57-44
Total Completed Inspections - 19
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/04/2001 | PLUMBING - ROUGH, SOIL | RCHAVEZ | Approved | IVRS - Inspection 0000* |
| 04/18/2001 | ROOF NAILING | DBRITO | Approved | IVRS - Inspection 0000* |
| 04/18/2001 | EXT METAL CLIPS/EXT SHEATHING | DBRITO | Approved | IVRS - Inspection 0000* |
| 04/25/2001 | FRAMING | DBRITO | Approved | IVRS - Inspection 0000*/1) NEGATIVE FLOW AT A/C UNIT DRAIN 2) REMOVE MESH AT DRY VENT 3) HINGE BRACING NOT PER PLAN |
| 04/25/2001 | FRAMING | DBRITO | Approved | IVRS - Inspection 0000* |
| 05/01/2001 | STUCCO MESH | DBRITO | Approved | IVRS - Inspection 0000* |
| 05/04/2001 | MECHANICAL - INTERMEDIATE | DBRITO | Approved | IVRS - Inspection 0000* |
| 05/04/2001 | PLUMBING - INTERMEDIATE | DBRITO | Approved | IVRS - Inspection 0000* |
| 05/04/2001 | ELECTRIC - INTERMEDIATE | DBRITO | Approved | IVRS - Inspection 0000* |
| 05/04/2001 | SHEET ROCK NAILING | DBRITO | Approved | IVRS - Inspection 0000* |
| 05/04/2001 | U VALUE FOR WINDOW | DBRITO | Approved | IVRS - Inspection 0000* |
| 06/21/2001 | PLUMBING - SEWER HCS CONNECT | RCHAVEZ | Approved | IVRS - Inspection 0000* |
| 06/21/2001 | PLUMBING - YARD WTR LINE/TEST | RCHAVEZ | Approved | IVRS - Inspection 0000* |
| 06/21/2001 | ELECTRIC - TEMPORARY SERVICE | RCHAVEZ | Approved | IVRS - Inspection 0000* |
| 06/21/2001 | ELECTRIC - CABLE DROP | RCHAVEZ | Approved | IVRS - Inspection 0000* |
| 07/16/2001 | PLUMBING - GAS PRESSURE TEST | RCHAVEZ | Approved | IVRS - Inspection 0000* |
| 07/17/2001 | MECHANICAL - FINAL | RCHAVEZ | Approved | IVRS - Inspection 0000* |
| 07/17/2001 | PLUMBING - FINAL | RCHAVEZ | Approved | IVRS - Inspection 0000* |
| 07/17/2001 | ELECTRIC - FINAL | RCHAVEZ | Approved | IVRS - Inspection 0000* |