Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY NEW
Apply Date:
03/16/2001
Applicant:
WRIGHT CONSTRUCTION INC , MARK
Description:
SFR:TD#14-33-10
Contractors:
  • WRIGHT CONSTRUCTION INC , MARK

Completed Inspections

Permit Status: Final
Permit Number: T01CM01305
Permit Description: SFR:TD#14-33-10
Total Completed Inspections - 22
Date Description Inspector Results Comments
04/10/2001 PLUMBING - SEWER HCS CONNECT RFREIDIN Approved IVRS - Inspection 0000*
04/10/2001 PLUMBING - ROUGH, SOIL RFREIDIN Approved IVRS - Inspection 0000*
04/16/2001 ELECTRIC - UFER RFREIDIN Approved IVRS - Inspection 0000*
04/16/2001 BUILDING PRE-SLAB RFREIDIN Approved IVRS - Inspection 0000*
04/16/2001 STEM WALL/RETAINING WALL RFREIDIN Approved IVRS - Inspection 0000*
04/16/2001 EXCAVATION/LAYOUT REBAR & ZON RFREIDIN Approved IVRS - Inspection 0000*
05/10/2001 ELECTRIC - TEMPORARY SERVICE RFREIDIN Approved IVRS - Inspection 0000*
05/10/2001 ELECTRIC - CABLE DROP RFREIDIN Approved IVRS - Inspection 0000*
05/16/2001 ROOF NAILING HSWENSON Approved IVRS - Inspection 0000*
05/16/2001 EXT METAL CLIPS/EXT SHEATHING HSWENSON Approved IVRS - Inspection 0000*
05/23/2001 MECHANICAL - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
05/23/2001 PLUMBING - GAS PRESSURE TEST RFREIDIN Approved IVRS - Inspection 0000*
05/23/2001 PLUMBING - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
05/23/2001 ELECTRIC - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
05/23/2001 FRAMING RFREIDIN Approved IVRS - Inspection 0000*/ 1) STRAP ACROSS TOP PLATE CUT/DRILLED TOO DEEP FOR 2 X 4 WALL MINIMUM METAL STRAP 16 GAUGE , 1 1/2 " WIDE BOTH PLATES SIX NAILS EACH SIDE 2) HANGERS AND TRUSS CLIPS REQUIRED 10D
06/11/2001 SHEET ROCK NAILING BSTEVENS Approved IVRS - Inspection 0000*
06/11/2001 STUCCO MESH BSTEVENS Approved IVRS - Inspection 0000*
07/24/2001 PERMIT FINALED RFREIDIN Approved
07/24/2001 MECHANICAL - FINAL RFREIDIN Approved IVRS - Inspection 0000*
07/24/2001 PLUMBING - FINAL RFREIDIN Approved IVRS - Inspection 0000*
07/24/2001 ELECTRIC - FINAL RFREIDIN Approved IVRS - Inspection 0000*
07/24/2001 BUILDING - FINAL RFREIDIN Approved IVRS - Inspection 0000*

Documents

File Name Document Type  
None CONSTRPLANS VIEW
None DOCUMENTS VIEW