Permit: T01CM01217
Permit Details
Status:
C of o
Type:
COMMERCIAL NEW
Address:
7401 E SPEEDWAY BL 20
Address NEW:
7401 E SPEEDWAY BL 20
Apply Date:
03/13/2001
Applicant:
SONORAN EXPEDITING
Description:
APARTMENTS:NEW BLDG 20
Architects:
- ACORN, KIM BRIAN
Permit Reviews
Permit Number - T01CM01217
Permit Status: C of o
Permit Description: APARTMENTS:NEW BLDG 20
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/13/2001 | 3RD PARTY REVIEW-COMMERCIAL | 03/29/2001 | COMPLETED |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM01217
Permit Description: APARTMENTS:NEW BLDG 20
Total Completed Inspections - 39
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/04/2001 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection 0000*1)SOIL WATER TEST OK.2)BUILDING DRAIN IS STUBBED OUT OF BUILDING AT 2-WAY C.O ONLY.3)OK TO BACKFILL TRENCH. |
| 06/11/2001 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | IVRS - Inspection 0000*1)HCS CONNECTION OF BUILDING DRAIN TO BUILDING SEWER OK.2)OK FOR BACKFILL. |
| 07/03/2001 | ELECTRIC - UFER | DSANTACR | Approved | IVRS - Inspection 0000*ALREADY APPROVED |
| 07/05/2001 | PLUMBING - PROGRESS | TRINIVJR | Approved | IVRS - Inspection 0000*1.) WATER SERVICE AIR PRESSURE TEST 60IBS IS OK 2.) WASTE & VENT WEAP IS OK |
| 07/05/2001 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection 0000* |
| 07/05/2001 | STEM WALL/RETAINING WALL | AMATHIES | Approved | IVRS - Inspection 0000* |
| 07/05/2001 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection 0000* |
| 09/13/2001 | ROOF NAILING | LHANLY | Approved | IVRS - Inspection 0000* |
| 09/19/2001 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 09/27/2001 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection 0000* |
| 10/04/2001 | PLUMBING - YARD WTR LINE/TEST | TRINIVJR | Approved | IVRS - Inspection 0000*1.) YARD WATER SERVICE FROM METER TO BLDG. SERVICE IS OK 2.) OK TO BACKFILL TRENCH. |
| 10/05/2001 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 10/22/2001 | ELECTRIC - CABLE DROP | DSANTACR | Approved | IVRS - Inspection 0000*OK CABLE DROP BLD #20 NO POWER YET. |
| 10/26/2001 | U VALUE FOR WINDOW | AMATHIES | Approved | IVRS - Inspection 0000* |
| 11/08/2001 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection 0000* |
| 11/09/2001 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000*1.) BE SURE AND HAVE CPVC PRESSURIZED BEFORE INSPECTOR ARRIVES.2.) IT IS IMPORTANT TO INSTALL PLUBING IN A WORKMANSHIP LIKE MANNER (NEATNESS COUNTS) PIPING SHALL NOT BENT OR STRAINED, AND SOLVENT CEMENT & PRIMER ON THE OUTSIDE OF THE PIPE AND FITTINGS DOES NOTHING TO INSURE WATE TIGHTNESS. 3.) SUPPORT VERTICAL PIPING AS NECESSARY 4.) OK TO COVER WALL 5.) CLOSET FLANGES OK. |
| 11/15/2001 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | |
| 12/12/2001 | STUCCO MESH | AMATHIES | Approved | IVRS - Inspection 0000* |
| 12/13/2001 | BUILDING - FINAL | AMATHIES | Approved | |
| 12/13/2001 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 01/29/2002 | MECHANICAL - TEMP PWR FOR TEST | JMILITEL | Approved | IVRS - Inspection 0000* |
| 01/29/2002 | PLUMBING - TEMP POWER FOR TEST | TRINIVJR | Approved | IVRS - Inspection 0000* |
| 01/29/2002 | BUILDING - TEMP POWER FOR TEST | AMATHIES | Approved | IVRS - Inspection 0000* |
| 03/05/2002 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |
| 03/07/2002 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection 0000* |
| 03/07/2002 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | 1.) PLBG FINAL IS OK 2.) OK FOR C OF O. |
| 03/07/2002 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection 0000* |
| 03/19/2002 | ELECTRIC - TEMP POWER FOR TEST | DSANTACR | Approved | IVRS - Inspection 0000* |
| 04/08/2002 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection 0000* |
| 04/08/2002 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection 0000* |
| 04/09/2002 | BUILDING ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 04/10/2002 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*OK FOR C OF O. |
| 04/30/2002 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | |
| 07/15/2002 | ENGINEERING - FINAL | DROBERTS | Approved | |
| 07/24/2002 | NPPO - FINAL | JLINVILL | Approved | |
| 07/24/2002 | LANDSCAPE - FINAL | JLINVILL | Approved | |
| 07/31/2002 | PERMIT FINALED | DSANTACR | Approved | |
| 07/31/2002 | ELECTRIC - TEMPORARY POLE | DSANTACR | Approved | |
| 07/31/2002 | ELECTRIC - UNDERGROUND | DSANTACR | Approved |