Permit: T01CM00566
Permit Details
Apply Date:
02/05/2001
Applicant:
JOHNSON SANDRA J
Description:
ADDITION:GARAGE (UNATTACHED)
Permit Reviews
Permit Number - T01CM00566
Permit Status: Expired
Permit Description: ADDITION:GARAGE (UNATTACHED)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/05/2001 | RESIDENTIAL BLDG/ZONING/FLOOD | 02/07/2001 | COMPLETED |
| 02/07/2001 | REVISION | 02/07/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM00566
Permit Status: Expired
Permit Description: ADDITION:GARAGE (UNATTACHED)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 02/05/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T01CM00566
Permite Description: ADDITION:GARAGE (UNATTACHED)
Total Outstanding Inspections - 5
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| BUILDING - FINAL | N/A | Not Inspected | ||
| ELECTRIC - FINAL | N/A | Not Inspected | ||
| 02/15/2001 | EXCAVATION/LAYOUT REBAR & ZON | N/A | Partial Approval | IVRS - Inspection 0000* |
| 02/15/2001 | BUILDING PRE-SLAB | N/A | Partial Approval | GAS LINE NOT PERMITTED UNDER GROUND UNDER BUILDING. OK TO POUR BUT GAS LINE MUST BE RELOCATED BEFORE BUILDING IS ENCLOSED. |
| 03/06/2001 | EXT METAL CLIPS/EXT SHEATHING | N/A | Partial Approval | IVRS - Inspection 0000*/1. X BRACE TRUSSES EA. END, YOU HAVE ONLY A DIAGONAL BRACE. 2. ALSO YOU NEED A LATERAL BRACE ON THE BOTTOM CHORD OF TRUSSES 10' O.C. IF TRUSSES ARE LEFT WITHOUT DRYWALL OR SHEATHING. 3. NEED EXPANSION ANCHORS MINIMUM 12" FROM EA. PLATE SPLICE. |
Completed Inspections
Permit Status: Expired
Permit Number: T01CM00566
Permit Description: ADDITION:GARAGE (UNATTACHED)
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/02/2001 | ROOF NAILING | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 04/27/2001 | ELECTRIC - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 04/27/2001 | FRAMING | RFREIDIN | Approved | IVRS - Inspection 0000* |