Permit: T01CM00401
Permit Details
Status:
Final
Type:
SINGLE FAMILY NEW
Address:
3882 E WHITE RIVER DR
Address NEW:
3882 E WHITE RIVER DR
Apply Date:
01/25/2001
Applicant:
NEW WORLD HOMES
Description:
SFR:TD#14-65-80
Contractors:
- NEW WORLD HOMES
Permit Reviews
Permit Number - T01CM00401
Permit Status: Final
Permit Description: SFR:TD#14-65-80
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/25/2001 | RESIDENTIAL BLDG/ZONING/FLOOD | 02/23/2001 | COMPLETED |
Completed Inspections
Permit Status: Final
Permit Number: T01CM00401
Permit Description: SFR:TD#14-65-80
Total Completed Inspections - 24
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/12/2001 | PLUMBING - SEWER HCS CONNECT | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 02/12/2001 | PLUMBING - YARD WTR LINE/TEST | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 02/12/2001 | PLUMBING - ROUGH, SOIL | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 02/20/2001 | ELECTRIC - UFER | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 02/20/2001 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 02/20/2001 | STEM WALL/RETAINING WALL | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 02/20/2001 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 03/05/2001 | ELECTRIC - TEMPORARY SERVICE | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 03/05/2001 | ELECTRIC - CABLE DROP | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 03/15/2001 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 03/15/2001 | EXT METAL CLIPS/EXT SHEATHING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 04/02/2001 | MECHANICAL - INTERMEDIATE | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 04/02/2001 | PLUMBING - GAS PRESSURE TEST | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 04/02/2001 | PLUMBING - INTERMEDIATE | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 04/02/2001 | ELECTRIC - INTERMEDIATE | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 04/02/2001 | FRAMING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 04/20/2001 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 04/20/2001 | STUCCO MESH | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 06/12/2001 | PERMIT FINALED | AQUIROZ | Approved | |
| 06/12/2001 | MECHANICAL - FINAL | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 06/12/2001 | PLUMBING - FINAL | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 06/12/2001 | ELECTRIC - FINAL | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 06/12/2001 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 06/12/2001 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection 0000* |