Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T01CM00385
Permit Details
Apply Date:
01/24/2001
Applicant:
ROBINSON, STEPHEN LYTLE
Description:
NEW OFFICE BLDG 2
Architects:
- ROBINSON, STEPHEN LYTLE
Contractors:
- BOCK BUILDING CONTRACTORS INC ,
Permit Reviews
Permit Number - T01CM00385
Permit Status: Final
Permit Description: NEW OFFICE BLDG 2
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/24/2001 | COMMERCIAL NEW | 04/09/2001 | COMPLETED |
05/23/2001 | REVISION | 11/01/2001 | COMPLETED |
Completed Inspections
Permit Status: Final
Permit Number: T01CM00385
Permit Description: NEW OFFICE BLDG 2
Total Completed Inspections - 28
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/24/2001 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection 0000* |
04/25/2001 | ELECTRIC - UFER | DSANTACR | Approved | IVRS - Inspection 0000* |
05/03/2001 | STEM WALL/RETAINING WALL | AMATHIES | Approved | IVRS - Inspection 0000* |
05/10/2001 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection 0000* 1) SOIL WATER TEST OK 2) THIS INSP IS FOR TRUNK LINE FOR SHELL ONLY 3) HCS CONNECTION AT P.L. OK 4) OK TO BACKFILL TRUNCK LINE ONLY NOT TI 5) WILL REQUIRE A REVISED AND APPROVED DRAWING ON WASTE TRUNK LINE BEFORE NEXT INSP |
05/24/2001 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | IVRS - Inspection 0000*1)SOIL WATER TEST OK.2)REVISED AND APPROVED DRAINING ON WASTE AND VENT SYSTEM OK.3)OK TO BACKFILL TRENCH. |
08/06/2001 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
08/06/2001 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | IVRS - Inspection 0000* |
08/16/2001 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection 0000*NOTES OK FOR SHELL PERIMETER BLD. LIGHTING. |
08/16/2001 | SHEET ROCK NAILING | AMATHIES | Approved | |
08/16/2001 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000* |
08/20/2001 | STUCCO MESH | AMATHIES | Approved | IVRS - Inspection 0000* |
09/05/2001 | ELECTRIC - TEMPORARY POLE | DSANTACR | Approved | |
09/05/2001 | ELECTRIC - TEMPORARY POLE | DSANTACR | Approved | IVRS - Inspection 0000*NOTES OK POLE BASES 4 TOTAL U.G. AND UFERS. |
09/28/2001 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection 0000* |
10/11/2001 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection 0000*1.) OK FOR GRID. |
10/11/2001 | BUILDING ABOVE CEILING | AMATHIES | Approved | IVRS - Inspection 0000* |
10/12/2001 | ELECTRIC - UNDERGROUND | AMATHIES | Approved | |
10/13/2001 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | |
11/16/2001 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*SHELL ONLY. |
11/16/2001 | SIGN - FINAL | DJOHNSTO | Approved | IVRS - Inspection 0000* |
11/16/2001 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection 0000* |
11/16/2001 | PLUMBING - YARD WTR LINE/TEST | TRINIVJR | Approved | IVRS - Inspection 0000*1.) PLBG FINAL IS OK 2.) THIS ACTIVITY IS FOR SHELL ONLY. |
11/30/2001 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection 0000* |
12/03/2001 | NPPO - FINAL | PGILBERT | Approved | |
12/03/2001 | LANDSCAPE - FINAL | PGILBERT | Approved | |
12/03/2001 | BUILDING - FINAL | AMATHIES | Approved | |
12/05/2001 | PERMIT FINALED | FIRE | Approved | |
12/05/2001 | ENGINEERING - FINAL | DROBERTS | Approved |