Outstanding Activity Conditions
Permit Number - T00PL02271
Permit Status: Expired
Permit Description: WATER HEATER
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/27/2000 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T00PL02271
Permite Description: WATER HEATER
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/13/2000 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection 0999* FLU VENT MUST BE SCREWED DOWN TO COLLAR AND ALL JOINTS IN FLU VENT MUST HAVE 1" CLEARANCE AROUND DBL WALL FLU VENT P&T DRAIN CAN ONLY HAVE 12" MAX OF FLEX LINE IN DRAIN LINE |