Permit: T00PL01877
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
2626 N AVENIDA CAROLINA
Address NEW:
2626 N AVENIDA CAROLINA
Apply Date:
10/11/2000
Applicant:
RIDHA HENRY MARK & RAJAA K JT/RS
Description:
REPAIR:GAS LINE
Permit Reviews
Permit Number - T00PL01877
Permit Status: Expired
Permit Description: REPAIR:GAS LINE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/11/2000 | PLUMBING | 10/12/2000 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T00PL01877
Permit Status: Expired
Permit Description: REPAIR:GAS LINE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/11/2000 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T00PL01877
Permite Description: REPAIR:GAS LINE
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/16/2000 | PLUMBING - INTERMEDIATE | N/A | Denied | IVRS - Inspection 0999* |
| 10/16/2000 | PLUMBING - GAS PRESSURE TEST | N/A | Denied | IVRS - Inspection 0999* GAS PRESSURE TEST MUST BE AT 10 LBS MIN MUST HAVE AGA APPROVED GAS SHUT OFF VALVES AT ALL APPLIANCES MUST HAVE 1" CLEARANCE AROUND DBL WALL FLU VENTS WATER HEATER P&T DRAIN MUST GO TO DAYLIGHT WITH APPROVED M ATERIAL MUST REMOVE ALL UNIONS IN LINE CAN NOT HAVE PVC GAS LINE IN SYSTEM MUST USE APPROVED MATERIAL MUST USE A LICENSE PLDG. CONTRACTOR TO DO WORK ON GAS LINE |
| 10/16/2000 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection 0999* |