Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
MOBILE HOME: MH PARK
Apply Date:
06/23/2000
Applicant:
DARNELL RUTH
Description:
MOBILE HOME:SETUP

Outstanding Inspections

Permit Status: Expired
Permit Number: T00MH00322
Permite Description: MOBILE HOME:SETUP
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
MOBILE HOME ACCESSORIES N/A Not Inspected
MOBILE HOME FINAL N/A Not Inspected
07/10/2000 MOBILE HOME UNDERGROUND GAS N/A Not ready for Inspection IVRS - Inspection 0000*
07/10/2000 MOBILE HOME PLUMBING N/A Denied IVRS - Inspection 0999*
1. SUPPORT WATER AND DRAIN LINES EVER 6'
2. CUT AND CAP UNUSED DRAIN PIPE LEAKING TO SOUTH CLOSET
3. DRAIN LINE NEED TO SLOPE 1/4" PER FOOT MINIMUM
4. RAINT EXPOSED ABS PIPE WITH WHITE LATEX PAINT
5. REPLACE PVC PIPE UNDER HOME WITH APPROVED MATERIAL (CPVC
6. INSTALL VACUUM BREAKER ON HOSE BIB

Documents

File Name Document Type  
None CONSTRPLANS VIEW