Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T00MH00046
Permit Details
Apply Date:
01/31/2000
Applicant:
KETOLA RUEBEN
Description:
MOBILE HOME:SETUP
Outstanding Inspections
Permit Status: Expired
Permit Number: T00MH00046
Permite Description: MOBILE HOME:SETUP
Total Outstanding Inspections - 4
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
MOBILE HOME FINAL | N/A | Not Inspected | ||
03/02/2000 | MOBILE HOME ACCESSORIES | N/A | Correction Required | ADDTL COMMS - DENIED - NOT READY. |
03/03/2000 | MOBILE HOME ELECTRICAL | N/A | Correction Required | ADDTL COMMS - 1. INSTALL SMOKE DETECTORS 245 2. INSTALL COVER PLATE OVER RECEPTACLE AT WASH MACHINE |
03/03/2000 | MOBILE HOME PLUMBING | N/A | Correction Required | ADDTL COMMS - 1. NO 340 PRESSURE ON GAS PIPING INFLATE TO 10 PSI MIN CHECK FOR AND REPAIR ANY LEAKS. RE INFLATE AND CALL FOR INSP. 2. NO WATER TEST ON WASTE PIPING, PLUG AT CONNECTION TO SEWER FILL TO FLOOR LEVEL AND CALL FOR INSPECTION |