Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T00EL02646
Permit Details
Apply Date:
11/13/2000
Applicant:
FLUORESCO LIGHTING MAINTENANCE C
Description:
ELEC:SIGN:1688
Contractors:
- FLUORESCO LIGHTING MAINTENANCE C
Outstanding Activity Conditions
Permit Number - T00EL02646
Permit Status: Final
Permit Description: ELEC:SIGN:1688
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
11/13/2000 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T00EL02646
Permit Description: ELEC:SIGN:1688
Total Completed Inspections - 5
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/20/2000 | SIGN SHOP | LHANLY | Approved | IVRS - Inspection 0000* |
01/26/2001 | SIGN ELECTRIC | LHANLY | Approved | IVRS - Inspection 0000* |
01/26/2001 | SIGN ELECTRIC | LHANLY | Approved | THERE IS A LOCAL AMENDMENT TO THE N.E.C. SECTION 350-14 THAT DISALLOWS FLEXIBLE METAL CONDUIT AS A GROUNDING MEANS. YOU WILL NEED TO RUN A #14 AWG (OR LORGER) AND TIE IT TO ALL FLEX CONDUIT AND FITTING ON THE SECONDARY SIDE OF TRANSFORMERS IDENTIFY BREAKER FOR SIGN AT SUB PANEL |
03/07/2001 | PERMIT FINALED | JSONKIN | Approved | |
03/07/2001 | SIGN INSPECTION | JSONKIN | Approved | IVRS - Inspection 0000* |