Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
229 W OHIO ST
Address NEW:
229 W OHIO ST
Apply Date:
06/30/2000
Applicant:
CHRIS FISHER
Description:
RECONNECT:ELELCTRIC:SFR

Outstanding Inspections

Permit Status: Expired
Permit Number: T00EL01650
Permite Description: RECONNECT:ELELCTRIC:SFR
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
ELECTRIC - FINAL N/A Not Inspected
07/03/2000 ELECTRIC - RECONNECT N/A Denied 1. COOLER SWITCH OUT OF WALL
2. 3 WIRE RECEPTACLES ON A 2 WIRE SYSTEM
3. NEED SMOKE DETECTORS
4. NEED LIGHT FIXTURE DURING ROOM
5. NEED FUSED OUTLET AT FURNACE
6. ZIP CORD TO XFMER ON WALL
7. DOUBLE LUG CONNECTIONS AT SERVICE
8. NON WEATHER PROOF BOX AT SERVICE
9. EXPOSED ROMEX AT REAR PORCH
10. NO COOLER
11. CONSTRUCTION IN PROGRESS NEED PERMIT FOR WORK
12. WATER HEATER NOT CONNECTED AND NEEDS ENCLOSURE
13. EXPOSED CONDUCERS AT FRONT LIGHT
14. NEED LICENSED CONTRACTORS

Documents

File Name Document Type  
None DOCUMENTS VIEW