Permit: T00EL01001
Permit Details
Apply Date:
04/18/2000
Applicant:
CARLTON REBECCA ELLEN
Description:
UPGRADE:ELECTRIC TO 200AMP (GARAGE)/ADD CIRCUITS
Outstanding Inspections
Permit Status: Expired
Permit Number: T00EL01001
Permite Description: UPGRADE:ELECTRIC TO 200AMP (GARAGE)/ADD CIRCUITS
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
ELECTRIC - INTERMEDIATE | N/A | Not Inspected | ||
06/20/2000 | ELECTRIC - SERVICE UPGRADE | N/A | Correction Required | ADDTL COMMS - 1. NEED PERMANENT ADDRESS ON METER BASE 2. NEED TO SEE GAS AND WATER BOND 3. NEED TO SEE INTERIOR 4. RODS OK DRIVE FLUSH OR BELOW GRADE 5. RISER REQUIRES A ROOF JACK AND ANOTHER SUPPORT AT HIGHEST DIAGONAL ROOF MEMBER. |
Completed Inspections
Permit Status: Expired
Permit Number: T00EL01001
Permit Description: UPGRADE:ELECTRIC TO 200AMP (GARAGE)/ADD CIRCUITS
Total Completed Inspections - 1
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/22/2000 | ELECTRIC - FINAL | JORTA | Approved | ADDTL COMMS - SERVICE UPGRADE CLEARANCE SUBJECT TO OBTAINING A PERMIT ADJUSTMENT FOR ADDITIONAL CIRCUITS (ALREADY APPROVED BY ELECTRICAL) 1-20 AMP FOR WINDOW A/C/ 1 -80 AMP FOR KILN 2-15 AMP FOR LIGHTING AND 2-20 AMP FOR GEN. RECEPT. 6 CIRCUITS PLEASE CLEAR W/TEP ONCE ABOVE IS OBTAINED |