Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
1909 E 8TH ST
Address NEW:
1909 E 8TH ST
Apply Date:
01/13/2000
Applicant:
TRUEBA JOSEPH M & GAIL M & TRUEB
Description:
UPGRADE:ELECTRIC 60 AMP TO 100 AMP
Contractors:
  • BERANEK ELECTRICAL SERVICE ,

Outstanding Inspections

Permit Status: Expired
Permit Number: T00EL00121
Permite Description: UPGRADE:ELECTRIC 60 AMP TO 100 AMP
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
01/21/2000 ELECTRIC - SERVICE UPGRADE N/A Correction Required ADDTL COMMS - 1. USE BREAKER SPECIFIED BY LABEL ONLY 2. NEED SEALING LOCKNUT 3. WILL NEED NEUTRAL FOR SUB PANEL ISOLATE (WITH WHITE TAPE NEUTRAL) GROUNDS AND NEUTRALS AT JUNCTION BOX 4. WILL NEED GAS BOND PLEASE CORRECT AND RECALL
02/08/2000 ELECTRIC - FINAL N/A Correction Required ADDTL COMMS - A REINSPECTION FEE IS DUE BEFORE THE NEXT INSPECTION 1. A SEALING LOCK NUT IS REQUIRED AT TOP OF PANEL

Documents

File Name Document Type  
None DOCUMENTS VIEW