Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T00CM06090
Permit Details
Apply Date:
12/19/2000
Applicant:
N/A
Description:
NEW:APARTMENTS
Architects:
- ACORN, KIM BRIAN
Contractors:
- T A-WALLICK LLC
Permit Reviews
Permit Number - T00CM06090
Permit Status: C of o
Permit Description: NEW:APARTMENTS
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
07/02/2001 | REVISION | 11/21/2001 | COMPLETED |
12/19/2000 | 3RD PARTY REVIEW-COMMERCIAL | 11/21/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T00CM06090
Permit Status: C of o
Permit Description: NEW:APARTMENTS
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
12/19/2000 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T00CM06090
Permit Description: NEW:APARTMENTS
Total Completed Inspections - 34
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/16/2002 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection 0000*1.) ABS UNDERGROUND OK 2.) WATER TEST RISERS ONLY ONE TO TEN FEET 3.) OK TO BACKFILL. |
02/25/2002 | ELECTRIC - UFER | JORTA | Approved | IVRS - Inspection 0000*BUILD NO 6 2 UFER SYSTEM ON ISOLATED 20' OF REBAR APPROVED. |
02/25/2002 | BUILDING PRE-SLAB | RSUBA | Approved | IVRS - Inspection 0000* |
04/22/2002 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
04/22/2002 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | IVRS - Inspection 0000* |
04/25/2002 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection 0000*1.) YARDWATER CONNECTIONS AT METER OK OK TO COVER. 2.) WILL CHECK CERTIFICATION OF RPBP ON FINAL. |
05/17/2002 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000*BLDG #06. 16 APTS. |
05/23/2002 | ELECTRIC - INTERMEDIATE | JORTA | Approved | IVRS - Inspection 0000* |
05/27/2002 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000*1.) ABS DWV OK THROUGH ROOF WATER TEST OK 2.) CPVC WATER TEST OK 3.) CLOSET FLANGES OK 4.) OK TO COVER ALL AREAS. |
05/31/2002 | STUCCO MESH | LHANLY | Approved | IVRS - Inspection 0000*STUCCO LATH APPROVED. |
05/31/2002 | FRAMING | LHANLY | Approved | IVRS - Inspection 0000* |
06/07/2002 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection 0000*TWO UNITS NOT READY. |
07/08/2002 | ELECTRIC - CABLE DROP | JORTA | Approved | PLEASE CLEAR C/D ONLY FOR SERVICE NO 1 AND 2. |
08/06/2002 | ELECTRIC - TEMP POWER FOR TEST | JORTA | Approved | IVRS - Inspection 0000*CLEARANCE SUBJECT TO LAST INSPECTOR ON SIGN OFF SHEET. |
08/07/2002 | PLUMBING - TEMP POWER FOR TEST | RMYERS | Approved | IVRS - Inspection 0000*OK FOR TEMP POWER. |
08/07/2002 | BUILDING - TEMP POWER FOR TEST | LHANLY | Approved | IVRS - Inspection 0000* |
08/08/2002 | MECHANICAL - TEMP PWR FOR TEST | CWILLIAM | Approved | IVRS - Inspection 0000* |
08/13/2002 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000*FINAL BLDG. #06. |
08/21/2002 | ELECTRIC - FINAL | JORTA | Approved | IVRS - Inspection 0000* |
08/27/2002 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0000*1.) BLDG DRAIN/BLDG SEWER CONNECTION MADE AT TIME OF SITE SEWER OK 2.) PLUMBING FINAL PER J STANLEY OK 3.) CONDENSATE CONNECTION, DOWNSTREAM OF GARBAGE DISPOSER AT KITCHEN SINK OK PER STEVE LONG. 4.) RPPBP CERTIFICATION ON FILE W/TUCSON WATER. 5.) OK FOR C OF O PENDING ANY OTHER INSPECTION. |
08/27/2002 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection 0000* |
08/27/2002 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | |
09/05/2002 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
09/05/2002 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
09/05/2002 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved | |
09/05/2002 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
09/05/2002 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection 0000* |
09/05/2002 | U VALUE FOR WINDOW | LHANLY | Approved | |
09/05/2002 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection 0000* |
09/10/2002 | RIGHT OF WAY - FINAL | LLOPEZ | Approved | |
09/10/2002 | SIGN - FINAL | JYBARRA | Approved | |
09/10/2002 | ENGINEERING - FINAL | LMAKUS | Approved | TEMPORARY C OF O APPROVED. FINAL NOT TO BE GIVEN UNTIL FINAL GRADING INSPECTION #9190 FOR GRADING PERMIT T01BU01801 HAS BEEN COMPLETED AND APPROVED. |
09/11/2002 | FIRE - FINAL | LTHOMAS | Approved | |
01/30/2003 | PERMIT FINALED | LHANLY | Approved |