Permit Details

Status:
C of o
Type:
COMMERCIAL NEW
Address:
5933 S 6TH AV 03
Apply Date:
12/19/2000
Applicant:
N/A
Description:
NEW:APARTMENTS BLDG 3
Architects:
  • ACORN, KIM BRIAN
Contractors:
  • T A-WALLICK LLC

Permit Reviews

Permit Number - T00CM06087
Permit Status: C of o
Permit Description: NEW:APARTMENTS BLDG 3
Start Date Submittal Complete Date Status  
07/02/2001 REVISION 11/21/2001 COMPLETED Review Details
12/19/2000 3RD PARTY REVIEW-COMMERCIAL 11/21/2001 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T00CM06087
Permit Status: C of o
Permit Description: NEW:APARTMENTS BLDG 3
Total Outstanding Activity Conditions - 1
Date Name
12/19/2000 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T00CM06087
Permit Description: NEW:APARTMENTS BLDG 3
Total Completed Inspections - 34
Date Description Inspector Results Comments
01/14/2002 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection 0000*1.) ABS DWV UNDERGROUND OK WATER TEST RISERS ONLY ONE TO TEN FEET 2.) OK TO BACKFILL.
02/12/2002 BUILDING PRE-SLAB LHANLY Approved IVRS - Inspection 0000*PLEASE FINISH TYING CABLES (EVERY OTHER INTERSECTION) & KEEP CHAIRS CLIPPED TO CABLE.
02/12/2002 EXCAVATION/LAYOUT REBAR & ZON LHANLY Approved IVRS - Inspection 0000*
02/15/2002 ELECTRIC - UFER JORTA Approved IVRS - Inspection 0000*WILL REQUIRE RODS TO OTHER AVAILABLE ELECTRODES (UFER NOT STANDING ALONE ON THIS PROJECT.) 2 SEPARATE UFERS.
04/10/2002 ROOF NAILING LHANLY Approved IVRS - Inspection 0000*
04/10/2002 EXT METAL CLIPS/EXT SHEATHING LHANLY Approved IVRS - Inspection 0000*
04/25/2002 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection 0000*1.) YARDWATER CONNECTS AT METER OK OK TO COVER. 2.) WILL CHECK CERTIFICATION OF RPBP ON FINAL.
05/03/2002 ELECTRIC - INTERMEDIATE JORTA Approved IVRS - Inspection 0000*
05/08/2002 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection 0000*BLDG #3.
05/08/2002 PLUMBING - INTERMEDIATE JSTANLEY Approved IVRS - Inspection 0000*CORRECTIONS HAVE BEEN MADE.
05/08/2002 FRAMING LHANLY Approved IVRS - Inspection 0000*1.) ON 2ND FLOOR, WHERE HOLE WAS MADE FOR PLUMBING @ PARTY WALL, YOU NEED TO PROVIDE DRAFT STOP. BLD 3 BETWEEN NORTHWEST & SOUTH WEST APTS.
05/16/2002 STUCCO MESH LHANLY Approved IVRS - Inspection 0000*
05/24/2002 SHEET ROCK NAILING LHANLY Approved IVRS - Inspection 0000*
06/19/2002 ELECTRIC - CABLE DROP JORTA Approved IVRS - Inspection 0000*WILL NEED TO HAVE A COMMON GROUNDING ELECTRODE SYSTEM BETWEEN SERVICES.
07/29/2002 ELECTRIC - FINAL JORTA Approved IVRS - Inspection 0000*
07/30/2002 ELECTRIC - TEMP POWER FOR TEST RMAJUTA Approved IVRS - Inspection 0000*
08/05/2002 MECHANICAL - FINAL CWILLIAM Approved
08/05/2002 MECHANICAL - TEMP PWR FOR TEST CWILLIAM Approved
08/07/2002 PLUMBING - TEMP POWER FOR TEST RMYERS Approved IVRS - Inspection 0000*OK FOR TEMP POWER.
08/13/2002 PLUMBING - FINAL RMYERS Approved IVRS - Inspection 0000*1.) PLEASE HAVE WATER TURNED ON TO EACH FIXTURE, AS WELL AS THE WATER HEATER AT THE TIME OF THE INSPECTION. 2.) CONTRACTOR IS REQUESTED TO PROCURE AND FILL OUT PETITION OF APPEAL" FOR THE VARIANCE CONCERNING THE TERMINUS OF THE CONDENSATE AT THE KITCHEN SINK TO BE FILED WITH CONTRACT DOCUMENTS. 3.) PLUMBING FINAL OK 4.) OK FOR C OF O PENDING ANY OTHER INSPECITONS RPPBP CERTIFICATION ON FILE WITH TUCSON WATER 5.) CONDENSATE TERMINATION AT KS PER S. LONG.
08/14/2002 FIRE - FINAL LTHOMAS Approved
08/14/2002 FIRE SPKLR - OH PIPING & HYDRO LTHOMAS Approved
08/14/2002 FIRE SPKLR - UG PIPING FLUSH LTHOMAS Approved
08/14/2002 FIRE SPKLR - UG, PIPING, HYDRO LTHOMAS Approved
08/14/2002 BUILDING - TEMP POWER FOR TEST LHANLY Approved IVRS - Inspection 0000*
08/15/2002 ENGINEERING - FINAL DROBERTS Approved TEMPORARY C OF O APPROVED FINAL NOT TO BE GIVEN UNTIL THE FINAL GRADING INSPECTION #9190 FOR T01BU01801 IS COMPLETED AND ACCEPTED
08/15/2002 FIRE SPKLR - FINAL LTHOMAS Approved ELECTRIC BOX OPEN IN RISER CLOSET. TAPE ON BELL BOX
08/15/2002 BUILDING - FINAL LHANLY Approved IVRS - Inspection 0000*PLUMBING, ELECTRIC, MECHANICAL FINALED. 2.) FIRE WANTS ENUNICATORS CONNECTED. 3.) PAINT OUT HC PARKING & PUT UP SIGNS.
08/15/2002 U VALUE FOR WINDOW LHANLY Approved IVRS - Inspection 0000*
08/16/2002 RIGHT OF WAY - FINAL LLOPEZ Approved
08/16/2002 SIGN - FINAL JYBARRA Approved
01/29/2003 PLUMBING - SEWER HCS CONNECT RMYERS Approved
01/29/2003 PLUMBING - GAS PRESSURE TEST RMYERS Approved
01/30/2003 PERMIT FINALED LHANLY Approved