Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY ALTERATION
Address NEW:
5883 S BLUCHER DR
Apply Date:
11/30/2000
Applicant:
MOORE MARK S & HOPE E
Description:
REMODEL:BATHROOM

Permit Reviews

Permit Number - T00CM05789
Permit Status: Final
Permit Description: REMODEL:BATHROOM
Start Date Submittal Complete Date Status  
11/30/2000 RESIDENTIAL BLDG/ZONING/FLOOD/WWM 02/21/2001 COMPLETED Review Details

Completed Inspections

Permit Status: Final
Permit Number: T00CM05789
Permit Description: REMODEL:BATHROOM
Total Completed Inspections - 4
Date Description Inspector Results Comments
12/05/2000 PLUMBING - ROUGH, SOIL RCHAVEZ Approved UNABLE TO DETERMINE WHETHER OR NOT CONCRETE FOUNDATION IS AN ENGINEERED POST TENSION SLAB. THERE IS NO STAMP IN THE CENTER OF GARAGE FLOOR, OR A TAG AT THE YARD WATER SHUT OFF VALVE. THERE IS A CABLE RUNNING NEXT TO THE 1 1/2 DRAIN AT TUB WHICH APPEARS TO BE A POST TENSION CABLE. YOU MAY CHECK RECORDS AT 201 N. STONE IN ORDER TO VARIFY SLAB. PRIOR TO NEXT INSPECTION EXPOSE ALL CONNECTIONS A SHOWER INSTALLATION REQUIRES 2" PLUMBING FROM TRAP TO SANITARY T CONNECTION YOU MAY WANT TO HIRE A LISCENSED PLUMBER.
12/13/2000 PLUMBING - INTERMEDIATE RCHAVEZ Approved IVRS - Inspection 0000*
01/03/2001 PERMIT FINALED RCHAVEZ Approved
01/03/2001 BUILDING - FINAL RCHAVEZ Approved IVRS - Inspection 0000*