Permit Details

Status:
Final
Type:
COMMERCIAL NEW
Address NEW:
1145 E VALENCIA RD
Apply Date:
11/27/2000
Applicant:
N/A
Description:
NEW:SHELL BUILDING
Contractors:
  • CANBERRA CONSTRUCTION COMPANY L L C

Permit Reviews

Permit Number - T00CM05729
Permit Status: Final
Permit Description: NEW:SHELL BUILDING
Start Date Submittal Complete Date Status  
03/09/2001 RESUBMITTAL 03/07/2002 COMPLETED Review Details
04/18/2002 REVISION 04/22/2002 COMPLETED Review Details
04/18/2002 REVISION 05/08/2002 COMPLETED Review Details
08/23/2002 REVISION 08/30/2002 COMPLETED Review Details
09/05/2002 REVISION 09/10/2002 COMPLETED Review Details
11/27/2000 COMMERCIAL NEW 03/09/2001 COMPLETED Review Details

Completed Inspections

Permit Status: Final
Permit Number: T00CM05729
Permit Description: NEW:SHELL BUILDING
Total Completed Inspections - 28
Date Description Inspector Results Comments
04/23/2002 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection 0000*1. PLAN REVISED AND APPROVED HAVE ARCHETECT CHANGE 4" TO 6" ON PLAN 2.) OK TO COVER 3.) WATER TEST OK.
05/09/2002 ELECTRIC - UFER DSANTACR Approved IVRS - Inspection 0000*NOTE OK 3/0 UFER, REBAR IS GROUNDING ELECTRODE.
05/09/2002 BUILDING PRE-SLAB LHANLY Approved IVRS - Inspection 0000*
05/09/2002 EXCAVATION/LAYOUT REBAR & ZON LHANLY Approved IVRS - Inspection 0000*1.) POST ADDRESS SO IT IS VISIBLE FROM STREET 2.) SOIL REPORT REVIEWED & ACCEPTED.
07/19/2002 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection 0000* 1.) REVIEWED DOCUMENT COVERING REVISION #4 CHANGE ORDER #1. 2.) YARDWATER FROM METER, THROUGH RPPBP, TO BLDG. SHUT OFF VALVE OK. 3.)PRESSURE TEST OK 4.) OK TO COVER.
08/13/2002 ELECTRIC - TEMPORARY POLE JORTA Approved
08/13/2002 ELECTRIC - CABLE DROP JORTA Approved
08/13/2002 ELECTRIC - INTERMEDIATE JORTA Approved IVRS - Inspection 0000*
08/13/2002 ELECTRIC - UNDERGROUND JORTA Approved
08/30/2002 ELECTRIC - FINAL JORTA Approved IVRS - Inspection 0000*
09/05/2002 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection 0000*APPROVED PLAN SHOWS EVAP. CLR. SCH. DELETED.
09/05/2002 MECHANICAL - INTERMEDIATE CWILLIAM Approved
09/05/2002 PLUMBING - FINAL RMYERS Approved IVRS - Inspection 0000*1.) THIS INSPECTION IS FOR SHELL BLDG. AND SITE UTILITIES ONLY. 2.) DO NOT REPLACE "TEMPORARY" HOSE BIBB WITHOUT INSTALLING A VACUUM BREAKER ON THE BIBB. 3.) CORRECTIONS MADE OK OK FOR C OF O PENDING ANY OTHER INSPECTION.
09/05/2002 PLUMBING - SEWER HCS CONNECT RMYERS Approved
09/13/2002 U VALUE FOR WINDOW LHANLY Approved IVRS - Inspection 0000*NO WINDOWS IN BUILDING.
09/13/2002 FRAMING LHANLY Approved IVRS - Inspection 0000*HIGHSTRENGH BOLTING INSPECTION DONE L1 KORY ENGINEERING PER STAMPED APPROVED SUBSTITUTE ENGINEER OF RECORD 7-18-02.
09/13/2002 EXT METAL CLIPS/EXT SHEATHING LHANLY Approved IVRS - Inspection 0000*
09/13/2002 REINFORCED MASONRY PRE-GROUT LHANLY Approved IVRS - Inspection 0000*PREGROUT NO MASONRY ON JOB.
09/13/2002 STEM WALL/RETAINING WALL LHANLY Approved IVRS - Inspection 0000*STEM WALL APPROVED NO STEMS.
09/25/2002 PERMIT FINALED LHANLY Approved
09/25/2002 BUILDING - FINAL LHANLY Approved IVRS - Inspection 0000*
09/25/2002 ROOF NAILING LHANLY Approved IVRS - Inspection 0000*
09/26/2002 FIRE - FINAL LTHOMAS Approved
09/26/2002 FIRE SPKLR - FINAL LTHOMAS Approved
09/26/2002 FIRE SPKLR - OH PIPING & HYDRO LTHOMAS Approved
09/26/2002 FIRE SPKLR - UG PIPING FLUSH LTHOMAS Approved
09/26/2002 FIRE SPKLR - UG, PIPING, HYDRO LTHOMAS Approved
01/31/2003 LANDSCAPE - FINAL PGILBERT Approved