Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T00CM05648
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
744 W PARIS PROMENADE
Address NEW:
744 W PARIS PROMENADE
Apply Date:
11/21/2000
Applicant:
KAREN SPEAR
Description:
REPLACE:WIRING & STUCCO
Permit Reviews
Permit Number - T00CM05648
Permit Status: Expired
Permit Description: REPLACE:WIRING & STUCCO
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/21/2000 | RESIDENTIAL BLDG/ZONING | 12/11/2000 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T00CM05648
Permit Status: Expired
Permit Description: REPLACE:WIRING & STUCCO
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/21/2000 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T00CM05648
Permite Description: REPLACE:WIRING & STUCCO
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| STUCCO MESH | N/A | Not Inspected | ||
| BUILDING - FINAL | N/A | Not Inspected | ||
| ELECTRIC - FINAL | N/A | Not Inspected | ||
| 12/14/2000 | ELECTRIC - INTERMEDIATE | N/A | Denied | IVRS - Inspection 0999*/1. THIS HOUSE HAS BEEN TOTALLY GUTTED AND REBUILT TO INCLUDE APPROXIMATELY 8FT EXTENSION AT FRONT NEW BEARING WALLS ON AN APPROXIMATE 30' X 30" ADDITION TO REAR WITH ALL NEW BEARING WALLS AND ROOF SYSTEM. PROVIDE APPROVED PLAN AND PERMIT FOR ALL WORK DONE IN PAST OR OBTAIN NEW PERMIT. NOTE NEW PLUMBING NOT TO CODE. 2. REVISE ELECTRIC PLAN FOR FORCED AIR ATTIC VENT. 3. GAS LINE MUST BE ELECTRICALLY BONDED. 4. DO NOT COVER WALLS, CEILING OF ANY UTILITIES PRIOR TO CONFIRMING APPROVED PLANS AND INSPECTIONS. 5. PROVIDE APPROVED TRUSS DRAWINGS |
Completed Inspections
Permit Status: Expired
Permit Number: T00CM05648
Permit Description: REPLACE:WIRING & STUCCO
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/23/2001 | ELECTRIC - TEMPORARY SERVICE | JRIVA | Approved | IVRS - Inspection 0000* |
| 02/23/2001 | ELECTRIC - CABLE DROP | JRIVA | Approved | IVRS - Inspection 0000* |