Permit: T00CM05137
Permit Details
Status:
Closed
Type:
DUPLEX ADDITION
Address:
334 W TENNESSEE ST #01
Address NEW:
334 W TENNESSEE ST #01
Apply Date:
10/16/2000
Applicant:
N/A
Description:
ADDITION: BEDROOM ON EACH DUPLEX
Contractors:
- RODRIGUEZ INC , C E
Permit Reviews
Permit Number - T00CM05137
Permit Status: Closed
Permit Description: ADDITION: BEDROOM ON EACH DUPLEX
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/07/2001 | RESUBMITTAL | 02/12/2001 | COMPLETED |
| 10/12/2001 | REVISION | 10/12/2001 | COMPLETED |
| 10/16/2000 | RESIDENTIAL BLDG/ZONING | 02/07/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T00CM05137
Permit Status: Closed
Permit Description: ADDITION: BEDROOM ON EACH DUPLEX
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/16/2000 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Closed
Permit Number: T00CM05137
Permite Description: ADDITION: BEDROOM ON EACH DUPLEX
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/12/2001 | ROOF NAILING | N/A | Denied | IVRS - Inspection 0999* |
| 10/12/2001 | BUILDING - FINAL | N/A | Denied | IVRS - Inspection 0999* |
Completed Inspections
Permit Status: Closed
Permit Number: T00CM05137
Permit Description: ADDITION: BEDROOM ON EACH DUPLEX
Total Completed Inspections - 12
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/06/2001 | EXCAVATION/LAYOUT REBAR & ZON | DWITT | Approved | IVRS - Inspection 0000* PORED WITH OUT INSP. HIRE A LICENCED GENERAL CONTRACTOR. HAVE THE CONTRACTOR CALL ME FOR THE FUTURE INSP. |
| 06/07/2001 | STEM WALL/RETAINING WALL | DWITT | Approved | IVRS - Inspection 0000*PLEASE PROVIDE THE APPROVED PLANS AND A LICENSED GENERAL CONTRACTOR LICENSE. |
| 10/12/2001 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection 0245*NOTES 1.) INSTALL CONNECTORS ON BOXES FOR ROMEX CONNECTIONS 2.) GROUND ALL SWITCHES AND OUTLETS. 3.) GROUND RODS TO BE AT LEAST 6' APART. 4.) INSTAL GROUNDING ELECTRODE CONDUCTOR. 5.) COMPLETE REPLACEMENT OF NEW PANEL IN BACK SERVICE. 6.) INSTALL SMOKE DETECTORS. 7.) APPERANTLY WORK WAS DONE WITHOUT INSPECTIONS. 8.) ALSO INSTALL BRACE FOR SERVICE RISER. 9.) INSTALL BOND TO GAS AND WATER PIPING FOR EACH UNIT. 10.) WORK TO BE DONE BY LICENSED COTNR. |
| 10/12/2001 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection 0245*NOTES 1.) INSTALL CONNECTORS ON BOXES FOR ROMEX CONNECTIONS.2.) GROUND ALL SWITCHES AND OUTLETS 3.) GROUND RODS TO BE AT LEAST 6" APART. 4.) INSTALL GROUNDING EECTRODE CONDUCTOR. 5.) COMPLETE REPLACEMENT OF NEW PANEL IN BACK SERVICE. 6.) INSTALL SMOKE DETECTORS 7.) APPREANTLY WORK WAS DONE WITHOUT INSPECTIONS. 8.) ALSO INSTALL BRACE FOR SERVICE RISER. 9.) INSTALL BOND TO GAS AND WATER PIPPING FOR EACH UNIT. 10.) WORK TO BE DONE BY LICESNSED CONTR. |
| 10/12/2001 | SHEET ROCK NAILING | LHANLY | Approved | IVRS - Inspection 0999* |
| 10/12/2001 | FRAMING | LHANLY | Approved | IVRS - Inspection 0999*1.) WORK COVERED BEFORE INSPECTION. 2.) PLAN SHOWS 2 X 8 RAFTERS ON NORTH & SOUTH ENDS PLEASE REVISE FOR 2 X 6 3.) REPLACE BOLTS FOR BEAM ANCHOR WITH 1/2" O.D. 4.) OPEN A SPACE IN CEILING OF BEDROOM SO I MAY SEE LEDGER. |
| 02/04/2002 | REINFORCED MASONRY PRE-GROUT | LHANLY | Approved | IVRS - Inspection 0000* |
| 02/04/2002 | BUILDING PRE-SLAB | LHANLY | Approved | IVRS - Inspection 0000* |
| 05/10/2002 | PLUMBING - GAS PRESS TEST FNL | JSTANLEY | Approved | IVRS - Inspection 0000*TEST OK WATER HEATER ONLY CALL GAS CO 889-1888. |
| 05/13/2002 | PLUMBING - FINAL | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 05/13/2002 | PLUMBING - GAS PRESSURE TEST | JSTANLEY | Approved | |
| 05/13/2002 | PLUMBING - INTERMEDIATE | JSTANLEY | Approved |