Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY NEW
Apply Date:
10/10/2000
Applicant:
CATALINA COMMUNITY BUILDERS L L
Description:
SFR:TD#14-50-62
Contractors:
  • CATALINA COMMUNITY BUILDERS L L

Completed Inspections

Permit Status: Final
Permit Number: T00CM05026
Permit Description: SFR:TD#14-50-62
Total Completed Inspections - 19
Date Description Inspector Results Comments
10/13/2000 PLUMBING - SEWER HCS CONNECT RAIELLO Approved IVRS - Inspection 0000*
10/13/2000 PLUMBING - YARD WTR LINE/TEST RAIELLO Approved IVRS - Inspection 0000*/1. YARD WATER NOT INSTALLED AT THIS TIME. 2. CONTRACTOR RESPONSIBLE FOR CLEAN FILL OVER ALL ABS AND WATER LINES PER UPC 315.4--ABC ON SITE
10/13/2000 PLUMBING - ROUGH, SOIL RAIELLO Approved IVRS - Inspection 0000*
10/18/2000 ELECTRIC - UFER RAIELLO Approved IVRS - Inspection 0000*
10/18/2000 BUILDING PRE-SLAB RAIELLO Approved IVRS - Inspection 0000*
10/18/2000 EXCAVATION/LAYOUT REBAR & ZON RAIELLO Approved IVRS - Inspection 0000*
11/01/2000 ELECTRIC - TEMPORARY SERVICE RAIELLO Approved IVRS - Inspection 0000*
11/01/2000 ELECTRIC - CABLE DROP RAIELLO Approved IVRS - Inspection 0000*
11/29/2000 ROOF NAILING DBRITO Approved IVRS - Inspection 0000*
11/29/2000 EXT METAL CLIPS/EXT SHEATHING DBRITO Approved IVRS - Inspection 0000*/PROVIDE LAGS AT POST BEAM CONNECTION AT PORCH.
01/08/2001 FRAMING DBRITO Approved IVRS - Inspection 0000*
01/30/2001 SHEET ROCK NAILING DBRITO Approved IVRS - Inspection 0000*
01/30/2001 U VALUE FOR WINDOW DBRITO Approved IVRS - Inspection 0000*
01/30/2001 STUCCO MESH DBRITO Approved IVRS - Inspection 0000*
03/28/2001 PERMIT FINALED DBRITO Approved
03/29/2001 MECHANICAL - FINAL DBRITO Approved IVRS - Inspection 0000*
03/29/2001 PLUMBING - FINAL DBRITO Approved IVRS - Inspection 0000*
03/29/2001 ELECTRIC - FINAL DBRITO Approved IVRS - Inspection 0000*
03/29/2001 BUILDING - FINAL DBRITO Approved IVRS - Inspection 0000*