Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY NEW
Address NEW:
6064 S GALIURO DR
Apply Date:
10/03/2000
Applicant:
NEW WORLD HOMES
Description:
SFR:TD#14-65-78
Contractors:
  • NEW WORLD HOMES

Permit Reviews

Permit Number - T00CM04908
Permit Status: Final
Permit Description: SFR:TD#14-65-78
Start Date Submittal Complete Date Status  
10/03/2000 RESIDENTIAL BLDG/ZONING/FLOOD 10/03/2000 COMPLETED Review Details

Completed Inspections

Permit Status: Final
Permit Number: T00CM04908
Permit Description: SFR:TD#14-65-78
Total Completed Inspections - 23
Date Description Inspector Results Comments
11/06/2000 PLUMBING - SEWER HCS CONNECT AQUIROZ Approved IVRS - Inspection 0000*
11/06/2000 PLUMBING - YARD WTR LINE/TEST AQUIROZ Approved IVRS - Inspection 0000*
11/06/2000 PLUMBING - ROUGH, SOIL AQUIROZ Approved IVRS - Inspection 0000*
11/09/2000 ELECTRIC - UFER AQUIROZ Approved IVRS - Inspection 0000*
11/09/2000 BUILDING PRE-SLAB AQUIROZ Approved IVRS - Inspection 0000*
11/09/2000 STEM WALL/RETAINING WALL AQUIROZ Approved IVRS - Inspection 0000*
11/09/2000 EXCAVATION/LAYOUT REBAR & ZON AQUIROZ Approved IVRS - Inspection 0000*
12/05/2000 ELECTRIC - TEMPORARY SERVICE AQUIROZ Approved IVRS - Inspection 0000*
12/13/2000 ROOF NAILING AQUIROZ Approved IVRS - Inspection 0000*
12/13/2000 EXT METAL CLIPS/EXT SHEATHING AQUIROZ Approved IVRS - Inspection 0000*
12/29/2000 MECHANICAL - INTERMEDIATE BSTEVENS Approved IVRS - Inspection 0999*
12/29/2000 PLUMBING - GAS PRESSURE TEST BSTEVENS Approved IVRS - Inspection 0000*
12/29/2000 PLUMBING - INTERMEDIATE BSTEVENS Approved IVRS - Inspection 0000*
12/29/2000 ELECTRIC - INTERMEDIATE BSTEVENS Approved IVRS - Inspection 0000*
12/29/2000 FRAMING BSTEVENS Approved IVRS - Inspection 0999*/1. FLEX DUCT BELOW CEILING IN LR 2. FLEX DUCT NOT INSTALLED PER UMC INSTALLATION STANDARDS OR MFR REQUIREMENTS. (MUST BE FULLY EXTENDED AND SOME BENDS ARE TOO TIGHT). FRAMING IS WITHHELD PENDING APPROVAL OF MECHANICAL.
01/19/2001 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection 0000*
01/19/2001 STUCCO MESH AQUIROZ Approved IVRS - Inspection 0000*
02/28/2001 PERMIT FINALED AQUIROZ Approved
02/28/2001 MECHANICAL - FINAL AQUIROZ Approved IVRS - Inspection 0000*
02/28/2001 PLUMBING - FINAL AQUIROZ Approved IVRS - Inspection 0000*
02/28/2001 ELECTRIC - FINAL AQUIROZ Approved IVRS - Inspection 0000*
02/28/2001 BUILDING - FINAL AQUIROZ Approved IVRS - Inspection 0000*
02/28/2001 U VALUE FOR WINDOW AQUIROZ Approved IVRS - Inspection 0000*