Permit: T00CM04261
Permit Details
Apply Date:
08/25/2000
Applicant:
FRANCISCO C & ELVA FIMBRES
Description:
DUPLEX:NEW
Permit Reviews
Permit Number - T00CM04261
Permit Status: Final
Permit Description: DUPLEX:NEW
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/26/2001 | RESUBMITTAL | 01/31/2001 | COMPLETED |
| 02/01/2001 | RESUBMITTAL | 02/06/2001 | COMPLETED |
| 09/07/2000 | RESIDENTIAL BLDG/ZONING/FLOOD/WWM | 01/26/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T00CM04261
Permit Status: Final
Permit Description: DUPLEX:NEW
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/25/2000 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T00CM04261
Permit Description: DUPLEX:NEW
Total Completed Inspections - 23
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/14/2001 | ELECTRIC - UFER | DWITT | Approved | IVRS - Inspection 0000* |
| 03/09/2001 | STEM WALL/RETAINING WALL | DWITT | Approved | IVRS - Inspection 0000* |
| 03/14/2001 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection 0000* NEED TO SEE REVISED APPROVED DRAWING FOR ACTUAL INSTALLATION OF BLDG DRAIN AND BLDG SEWER. OK TO BACKFILL |
| 03/14/2001 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection 0000* |
| 03/21/2001 | BUILDING PRE-SLAB | DWITT | Approved | IVRS - Inspection 0000* |
| 03/21/2001 | EXCAVATION/LAYOUT REBAR & ZON | DWITT | Approved | IVRS - Inspection 0000* |
| 04/10/2001 | REINFORCED MASONRY PRE-GROUT | DWITT | Approved | IVRS - Inspection 0000* |
| 05/01/2001 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 05/21/2001 | PLUMBING - GAS PRESSURE TEST | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 05/21/2001 | PLUMBING - INTERMEDIATE | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 05/21/2001 | ELECTRIC - INTERMEDIATE | JORTA | Approved | IVRS - Inspection 0000* |
| 05/21/2001 | U VALUE FOR WINDOW | DWITT | Approved | IVRS - Inspection 0000* |
| 05/21/2001 | FRAMING | DWITT | Approved | IVRS - Inspection 0000* |
| 05/24/2001 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000*EVAP. COOLER LOCATION IS NOT INDICATED ON MECH. OWNER SHOULD BE ADVISED OF LOCATION AND PERFORMANCE W/WALL LOCATION. |
| 06/04/2001 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 06/11/2001 | ELECTRIC - CABLE DROP | RMAJUTA | Approved | IVRS - Inspection 0000*STRAP GROUND WIRE TO WALL BELOW SERVICE. |
| 07/09/2001 | ELECTRIC - TEMPORARY SERVICE | RHOLLAND | Approved | IVRS - Inspection 0000*OK TEMP POWER FOR TESTING ONLY. |
| 08/20/2001 | ELECTRIC - FINAL | JORTA | Approved | IVRS - Inspection 0000* |
| 08/27/2001 | PERMIT FINALED | LHANLY | Approved | |
| 08/27/2001 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000*PARTIAL 8/24/01 |
| 08/27/2001 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0000* |
| 08/27/2001 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection 0000*1.) PEX PIPING FROM METER TO BLDG OK TWO PLACES TRANSITION FITTINGS OK PRESSURE TEST OK 2.0 OK TO BACKFILL 3.) OK FOR C OF O. PENDING ANY OTHER INSPECTIONS 4. UCC LEFT AT METERS. |
| 08/27/2001 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection 0000* |