Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY NEW
Address:
3822 N BORG LN
Address NEW:
3822 N BORG LN
Apply Date:
05/31/2000
Applicant:
LANTANA CORPORATION
Description:
TOWNHOUSE:TD#14-03-33
Contractors:
  • LANTANA CORPORATION

Completed Inspections

Permit Status: Final
Permit Number: T00CM02747
Permit Description: TOWNHOUSE:TD#14-03-33
Total Completed Inspections - 16
Date Description Inspector Results Comments
09/20/2000 ELECTRIC - TEMPORARY SERVICE DSANTACR Approved IVRS - Inspection 0000*
OK TO CLEAR OK CABLE DROP
09/20/2000 ELECTRIC - CABLE DROP DSANTACR Approved IVRS - Inspection 0000*
10/02/2000 FRAMING AMATHIES Approved IVRS - Inspection 0000*
10/02/2000 ROOF NAILING AMATHIES Approved IVRS - Inspection 0000*
10/02/2000 EXT METAL CLIPS/EXT SHEATHING AMATHIES Approved IVRS - Inspection 0000*
11/14/2000 PLUMBING - GAS PRESSURE TEST RMYERS Approved IVRS - Inspection 0000*
11/14/2000 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection 0000*
abs dwv ok water test ok
pex piping ok
PRESSURE TEST OK
GAS PRESSURE TEST OK PIPING OK OK TO COVER WALLS
11/15/2000 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection 0000*
PLASTIC PUSH IN BUSHING NOT ALLOWED UNLESS TABS CRIMP ROMEX
11/16/2000 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection 0000*
11/17/2000 STUCCO MESH AMATHIES Approved IVRS - Inspection 0000*
04/11/2001 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection 0000*
04/11/2001 PLUMBING - FINAL FMCCLURE Approved IVRS - Inspection 0000*
04/12/2001 PERMIT FINALED EMONAHAN Approved
04/12/2001 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection 0000*
04/12/2001 BUILDING - FINAL EMONAHAN Approved IVRS - Inspection 0000*
04/12/2001 U VALUE FOR WINDOW EMONAHAN Approved