Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Details

Status:
Expired
Type:
SINGLE FAMILY ADDITION
Address NEW:
5531 E FAIRMOUNT ST
Apply Date:
04/12/2000
Applicant:
HOLGUIN SEAN E
Description:
ADDITION:CARPORT T99VL02515:GAS LINE:NEW
Contractors:
  • SANDERS PLUMBING AND RESIDENTIAL

Outstanding Inspections

Permit Status: Expired
Permit Number: T00CM01863
Permite Description: ADDITION:CARPORT T99VL02515:GAS LINE:NEW
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
PLUMBING - FINAL N/A Not Inspected
04/14/2000 FRAMING N/A Correction Required ADDTL COMMS - NOT READY - NO -ONE AT HOME. PLEASE RECALL INSPECTION.
04/24/2000 BUILDING - FINAL N/A Not ready for Inspection IVRS - Inspection 0000*/1. DIG INSPECTION HOLE AT ONE FTG. WEST SIDE 2. SPAN ON EAST SIDE NO PER PLAN OVER 9'. 3. PLYWOOD IS ALREADY COVERED WITH ROOFING. 4. POST TO BEAM CONNECTIONS NOT ON PLAN. 5. POST BEAM INSTALLED WITH OUT SPACER PLATE AT WOOD TO STEEL. 6. PUT ROMEX IN CONDUIT FOR CIRCUIT NOT INDICATED ON PLAN. 7. STRUCTURE IS VERY WOBBLEY, SHOULD BE ATTACHED TO THE EXISTING STRUCTURE. 8. PLAN SHOWS 18' SPAN I MEASURE 18'6" 2 X 10 AT 24" O.C. SHOW ONLY SPAN 16' 3"? PLUS HEADER AT F/PLACE.