Permit: T00CM00871
Permit Details
Status:
Expired
Type:
SINGLE FAMILY ALTERATION
Address:
102 W VETERANS BL #04
Address NEW:
102 W VETERANS BL #04
Apply Date:
02/24/2000
Applicant:
TAMAYO GREGORIO & MERCEDES L JT/
Description:
REMODEL:WH/LAV/KIT FAUCET/BASE BD HTR T99VL01713
Outstanding Inspections
Permit Status: Expired
Permit Number: T00CM00871
Permite Description: REMODEL:WH/LAV/KIT FAUCET/BASE BD HTR T99VL01713
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/02/2000 | ELECTRIC - FINAL | N/A | Correction Required | ADDTL COMMS - DENIED - 1. ELECTRIC PANEL DOES NOT HAVE CIRCUITS LABELED. 2. DWV WASTE VENTS MUST EXTEND 6 ABOVE ROOF. 3. ABS AND PVC. DWV PIPE CANNOT BE INTERMIXED. 4. ABS, PVC, CPVC PLUMBING CANNOT BE USED ON EXTERIOR OF BUILDING UNPROTECTED. 5. WATER HEATER P & T VALVE DRAIN TUB MUST BE 3/4 MINIMUM. 6. WATER HEATER JUNCTION BOX IS NOT SECURE TO THE WALL AND MUST BE ELECTRICALLY BONDED. 7. W/C (TOILET) MUST HAVE 2 WASTE VENT. |
| 03/02/2000 | PLUMBING - INTERMEDIATE | N/A | Denied | IVRS - Inspection 0999* |
| 03/02/2000 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection 0999* |