Permit: T00CM00753
Permit Details
Apply Date:
02/16/2000
Applicant:
DAVID EVANS AND ASSOCIATES
Description:
RETAIL BUILDING
Contractors:
- CHESTNUT CONSTRUCTION CORPORATIO
Permit Reviews
Permit Number - T00CM00753
Permit Status: C of o
Permit Description: RETAIL BUILDING
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/12/2000 | COMMERCIAL NEW | 11/27/2000 | COMPLETED |
| 12/06/2000 | REVISION | 01/22/2001 | COMPLETED |
Completed Inspections
Permit Status: C of o
Permit Number: T00CM00753
Permit Description: RETAIL BUILDING
Total Completed Inspections - 22
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/05/2000 | STEM WALL/RETAINING WALL | DWITT | Approved | IVRS - Inspection 0000* |
| 10/10/2000 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection 0000* 1. SOIL WATER TEST OK 2. OK TO BACKFILL TRENCH 3. BLDG DRAIN IS STUBBED OUT OF BLDG ONLY 4. NOTE: WILL REQUIRE REVISED AND APPROVED DRAINING ON WASTE AND VENT SYSTEM FOR RESTROOM BEFORE NEXT INPSECTION |
| 10/27/2000 | REINFORCED MASONRY PRE-GROUT | DWITT | Approved | IVRS - Inspection 0000* |
| 10/31/2000 | BUILDING PRE-SLAB | DWITT | Approved | IVRS - Inspection 0000* |
| 11/03/2000 | ELECTRIC - UNDERGROUND | MCAPISTR | Approved | IVRS - Inspection 0000* LIGHT POLES REAR AND WEST SIDE AND 3 ON NORTHSIDE |
| 12/04/2000 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | IVRS - Inspection 0000* GAS DROP IN EAST WALL OK OK TO DRYWALL |
| 12/07/2000 | EXCAVATION/LAYOUT REBAR & ZON | DWITT | Approved | IVRS - Inspection 0000* |
| 12/08/2000 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection 0000* WASTE AND VENT SYSTEM OK OVERHEAD WATER DISTRIBUTION OK OK FOR DRYWALL THIS INSPECTION IS FOR RESTROOM ONLY |
| 12/09/2000 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 12/11/2000 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | IVRS - Inspection 0000* |
| 12/15/2000 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection 0000* FRONT ENTRANCE CIELING RECESSED LITES ROUGH OK NO HOUSINGS INSTALLED |
| 12/20/2000 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection 0000* INSPECTION ON FIRE DAMPER ONLY OK TO PROCEED |
| 12/31/2000 | STUCCO MESH | DWITT | Approved | IVRS - Inspection 0000* FRONT PORTION OF BUILDING |
| 01/08/2001 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection 0000* SUSPENDED DUCT, FLEX AND DIFFUSERS OK TO COVER CEILING |
| 01/08/2001 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection 0000* CONDENSATE DRAINS ABOVE CEILING OK OK FOR GRID |
| 01/11/2001 | ELECTRIC - ABOVE CEILING | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 01/12/2001 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000* |
| 02/09/2001 | SIGN - FINAL | JSONKIN | Approved | IVRS - Inspection 0000* |
| 02/09/2001 | ELECTRIC - FINAL | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 02/09/2001 | ELECTRIC - CABLE DROP | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 02/09/2001 | BUILDING - FINAL | DWITT | Approved | IVRS - Inspection 0000* |
| 02/12/2001 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection 0000* OK FOR C OF O |