Permit: T00CM00699
Permit Details
Apply Date:
02/14/2000
Applicant:
ROLLINGS TRUST
Description:
TI:OFFICE
Permit Reviews
Permit Number - T00CM00699
Permit Status: Expired
Permit Description: TI:OFFICE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
02/28/2001 | RESUBMITTAL | 03/05/2001 | COMPLETED |
03/05/2001 | COMMERCIAL TI | 04/17/2001 | COMPLETED |
03/05/2001 | SITE | 04/05/2001 | COMPLETED |
04/05/2001 | RESUBMITTAL | 04/17/2001 | COMPLETED |
04/17/2001 | RESUBMITTAL | 04/20/2001 | COMPLETED |
04/26/2001 | RESUBMITTAL | 05/14/2001 | COMPLETED |
11/02/2000 | COMMERCIAL TI | 02/28/2001 | COMPLETED |
11/02/2000 | SITE | 01/03/2001 | COMPLETED |
Outstanding Inspections
Permit Status: Expired
Permit Number: T00CM00699
Permite Description: TI:OFFICE
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/07/2002 | BUILDING - FINAL | N/A | Partial Approval | IVRS - Inspection 0000*OK FOR T.C.O. PLAN INDICATES ACCESSIBLE ROUTE FROM CONVENT ST. TO BREEZEWAY @ SOUTH SIDE OF BUILDING. PLAN ALSO SHOW PAVED PARKINGS. PLEASE REVISE PLAN OR COMPLETE PER PLAN. |
11/19/2001 | BUILDING - PROGRESS | N/A | Partial Approval | IVRS - Inspection 0000*SOME FRAMING & ROOF JOISTS. |
Completed Inspections
Permit Status: Expired
Permit Number: T00CM00699
Permit Description: TI:OFFICE
Total Completed Inspections - 18
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/07/2002 | ELECTRIC - UNDERGROUND | JORTA | Approved | IVRS - Inspection 0000* 2" PVC FOR PANEL "A" APPROVED 2" TELE. PVC APPROVED. WILL NEED REQUIRED 'UFER' GROUND SYSTEM FOR NEW PANEL BOARDS FOR PANEL A AND B. NOTE: PLEASE TIE REBAR TO GROUND ROD. |
03/12/2002 | ELECTRIC - UFER | JORTA | Approved | IVRS - Inspection 0000*UFER SYSTEM @ PANEL A AND B APPROVED TIED TOGETHER THROUGH REBAR. SERVICE SWITCH BOARD GROUND ROD SYSTEM GROUNDED TO REBAR IN FOOTING ALSO. |
04/19/2002 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection 0000* |
04/19/2002 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection 0000*1.) ABS UNDERGROUND OK WATER TEST OK 2.) BLDG SEWER OK FROM TWO WAY TO TIE-IN AT EXISTING WATER TEST OK 3.) OK TO BACKFILL. |
08/01/2002 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection 0000*INSPECTED EXHAUST & SUPPLY DUCTS ABOVE HARD CEILING OK FOR SHEET ROCK NOTE CONDENSATE DRAINS WILL BE TERMINATED INTO PLANTERS. |
08/08/2002 | ELECTRIC - INTERMEDIATE | RMAJUTA | Approved | WATER LINE ABOVE PNL MOVED. FHA STRAP ON PVC OK. |
08/12/2002 | BUILDING PRE-SLAB | LHANLY | Approved | |
08/14/2002 | FRAMING | LHANLY | Approved | IVRS - Inspection 0000* |
08/28/2002 | SHEET ROCK NAILING | LHANLY | Approved | IVRS - Inspection 0000* |
10/03/2002 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000*CLOSET FLANGES OK . |
11/04/2002 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | |
11/05/2002 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
11/05/2002 | PLUMBING - PROGRESS | RMYERS | Approved | IVRS - Inspection 0000* |
11/05/2002 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection 0000* |
11/05/2002 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection 0000* |
11/05/2002 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection 0000* |
11/05/2002 | ELECTRIC - FINAL | RMAJUTA | Approved | IVRS - Inspection 0000*CONTRACTOR TO SUPPORT AC EQUIPMENT SEAL TIGHT OF ROOF. |
11/07/2002 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0000* 1.) PLUMBING FINAL OK 2.) OK FOR C OF O PENDING ANY OTHER INSPECTIONS. |