Permit: T00CM00206
Permit Details
Status:
Expired
Type:
COMMERCIAL NEW
Address:
8031 E LAKESIDE PW 01
Address NEW:
8031 E LAKESIDE PW 01
Apply Date:
01/18/2000
Applicant:
PETRICK KEVIN
Description:
SHELL BUILDING 300' -6 1/2" x 110'-6 1/2" SHELL BUILDING, TILTUP CONCRETE W/ WOOD ROOF , GLU-LAM BEAMS, STEEL COLUMNS AND WOOD TRUSSES, MASONRY IS USED AT ENTRY PORCHES,W/ CHAINLINK AT YARDS ATTACHED TO BUILDING.
Permit Reviews
Permit Number - T00CM00206
Permit Status: Expired
Permit Description: SHELL BUILDING 300' -6 1/2" x 110'-6 1/2" SHELL BUILDING, TILTUP CONCRETE W/ WOOD ROOF , GLU-LAM BEAMS, STEEL COLUMNS AND WOOD TRUSSES, MASONRY IS USED AT ENTRY PORCHES,W/ CHAINLINK AT YARDS ATTACHED TO BUILDING.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/22/2001 | RESUBMITTAL | 02/08/2001 | COMPLETED |
| 02/08/2001 | RESUBMITTAL | 02/14/2001 | STOPPED |
| 12/06/2000 | COMMERCIAL NEW | 01/22/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T00CM00206
Permit Status: Expired
Permit Description: SHELL BUILDING 300' -6 1/2" x 110'-6 1/2" SHELL BUILDING, TILTUP CONCRETE W/ WOOD ROOF , GLU-LAM BEAMS, STEEL COLUMNS AND WOOD TRUSSES, MASONRY IS USED AT ENTRY PORCHES,W/ CHAINLINK AT YARDS ATTACHED TO BUILDING.
Total Outstanding Activity Conditions - 8
| Date | Name |
|---|---|
| 02/13/2001 | SPECIAL INSPECTION FOR CONCRETE IS REQUIRED.. |
| 02/13/2001 | SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED. |
| 02/13/2001 | SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED. |
| 02/13/2001 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
| 02/13/2001 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 02/13/2001 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. |
| 02/13/2001 | SHOP DRAWINGS REQUIRED FOR: 1. WOOD ROOF TRUSSES 2. METAL AWNINGS 3. METAL FACIA |
| 02/13/2001 | SPECIAL INSPECTION IS REQUIRED FOR ??? PER U.A.C. SECTION 306. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T00CM00206
Permite Description: SHELL BUILDING 300' -6 1/2" x 110'-6 1/2" SHELL BUILDING, TILTUP CONCRETE W/ WOOD ROOF , GLU-LAM BEAMS, STEEL COLUMNS AND WOOD TRUSSES, MASONRY IS USED AT ENTRY PORCHES,W/ CHAINLINK AT YARDS ATTACHED TO BUILDING.
Total Outstanding Inspections - 25
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| EXCAVATION/LAYOUT REBAR & ZON | N/A | Not Inspected | ||
| STEM WALL/RETAINING WALL | N/A | Not Inspected | ||
| BUILDING PRE-SLAB | N/A | Not Inspected | ||
| REINFORCED MASONRY PRE-GROUT | N/A | Not Inspected | ||
| EXT METAL CLIPS/EXT SHEATHING | N/A | Not Inspected | ||
| ROOF NAILING | N/A | Not Inspected | ||
| FRAMING | N/A | Not Inspected | ||
| BUILDING - FINAL | N/A | Not Inspected | ||
| ELECTRIC - UFER | N/A | Not Inspected | ||
| ELECTRIC - UNDERGROUND | N/A | Not Inspected | ||
| ELECTRIC - INTERMEDIATE | N/A | Not Inspected | ||
| ELECTRIC - ABOVE CEILING | N/A | Not Inspected | ||
| ELECTRIC - FINAL | N/A | Not Inspected | ||
| OUTDOOR LIGHTING FINAL | N/A | Not Inspected | ||
| PLUMBING - ROUGH, SOIL | N/A | Not Inspected | ||
| PLUMBING - YARD WTR LINE/TEST | N/A | Not Inspected | ||
| PLUMBING - SEWER HCS CONNECT | N/A | Not Inspected | ||
| PLUMBING - PROGRESS | N/A | Not Inspected | ||
| PLUMBING - FINAL | N/A | Not Inspected | ||
| FIRE SPKLR - UG, PIPING, HYDRO | N/A | Not Inspected | ||
| FIRE SPKLR - UG PIPING FLUSH | N/A | Not Inspected | ||
| FIRE SPKLR - OH PIPING & HYDRO | N/A | Not Inspected | ||
| FIRE SPKLR - FINAL | N/A | Not Inspected | ||
| FIRE - HYDRANTS | N/A | Not Inspected | ||
| FIRE - FINAL | N/A | Not Inspected |