Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
COMMERCIAL NEW
Apply Date:
01/18/2000
Applicant:
PETRICK KEVIN
Description:
SHELL BUILDING 300' -6 1/2" x 110'-6 1/2" SHELL BUILDING, TILTUP CONCRETE W/ WOOD ROOF , GLU-LAM BEAMS, STEEL COLUMNS AND WOOD TRUSSES, MASONRY IS USED AT ENTRY PORCHES,W/ CHAINLINK AT YARDS ATTACHED TO BUILDING.

Permit Reviews

Permit Number - T00CM00206
Permit Status: Expired
Permit Description: SHELL BUILDING 300' -6 1/2" x 110'-6 1/2" SHELL BUILDING, TILTUP CONCRETE W/ WOOD ROOF , GLU-LAM BEAMS, STEEL COLUMNS AND WOOD TRUSSES, MASONRY IS USED AT ENTRY PORCHES,W/ CHAINLINK AT YARDS ATTACHED TO BUILDING.
Start Date Submittal Complete Date Status  
01/22/2001 RESUBMITTAL 02/08/2001 COMPLETED Review Details
02/08/2001 RESUBMITTAL 02/14/2001 STOPPED Review Details
12/06/2000 COMMERCIAL NEW 01/22/2001 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T00CM00206
Permit Status: Expired
Permit Description: SHELL BUILDING 300' -6 1/2" x 110'-6 1/2" SHELL BUILDING, TILTUP CONCRETE W/ WOOD ROOF , GLU-LAM BEAMS, STEEL COLUMNS AND WOOD TRUSSES, MASONRY IS USED AT ENTRY PORCHES,W/ CHAINLINK AT YARDS ATTACHED TO BUILDING.
Total Outstanding Activity Conditions - 8
Date Name
02/13/2001 SPECIAL INSPECTION FOR CONCRETE IS REQUIRED..
02/13/2001 SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED.
02/13/2001 SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED.
02/13/2001 SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED.
02/13/2001 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
02/13/2001 SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED.
02/13/2001 SHOP DRAWINGS REQUIRED FOR: 1. WOOD ROOF TRUSSES 2. METAL AWNINGS 3. METAL FACIA
02/13/2001 SPECIAL INSPECTION IS REQUIRED FOR ??? PER U.A.C. SECTION 306.

Outstanding Inspections

Permit Status: Expired
Permit Number: T00CM00206
Permite Description: SHELL BUILDING 300' -6 1/2" x 110'-6 1/2" SHELL BUILDING, TILTUP CONCRETE W/ WOOD ROOF , GLU-LAM BEAMS, STEEL COLUMNS AND WOOD TRUSSES, MASONRY IS USED AT ENTRY PORCHES,W/ CHAINLINK AT YARDS ATTACHED TO BUILDING.
Total Outstanding Inspections - 25
Last Inspection Date Description Inspector Results Comments
EXCAVATION/LAYOUT REBAR & ZON N/A Not Inspected
STEM WALL/RETAINING WALL N/A Not Inspected
BUILDING PRE-SLAB N/A Not Inspected
REINFORCED MASONRY PRE-GROUT N/A Not Inspected
EXT METAL CLIPS/EXT SHEATHING N/A Not Inspected
ROOF NAILING N/A Not Inspected
FRAMING N/A Not Inspected
BUILDING - FINAL N/A Not Inspected
ELECTRIC - UFER N/A Not Inspected
ELECTRIC - UNDERGROUND N/A Not Inspected
ELECTRIC - INTERMEDIATE N/A Not Inspected
ELECTRIC - ABOVE CEILING N/A Not Inspected
ELECTRIC - FINAL N/A Not Inspected
OUTDOOR LIGHTING FINAL N/A Not Inspected
PLUMBING - ROUGH, SOIL N/A Not Inspected
PLUMBING - YARD WTR LINE/TEST N/A Not Inspected
PLUMBING - SEWER HCS CONNECT N/A Not Inspected
PLUMBING - PROGRESS N/A Not Inspected
PLUMBING - FINAL N/A Not Inspected
FIRE SPKLR - UG, PIPING, HYDRO N/A Not Inspected
FIRE SPKLR - UG PIPING FLUSH N/A Not Inspected
FIRE SPKLR - OH PIPING & HYDRO N/A Not Inspected
FIRE SPKLR - FINAL N/A Not Inspected
FIRE - HYDRANTS N/A Not Inspected
FIRE - FINAL N/A Not Inspected

Documents

File Name Document Type  
None DOCUMENTS VIEW