Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: DP19-0048
Permit Details
Apply Date:
02/22/2019
Applicant:
Robert Lanning
Description:
SITE - La Suprema Co-Working.
Permit Reviews
Permit Number - DP19-0048
Permit Status: Complete
Permit Description: SITE - La Suprema Co-Working.
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
02/22/2019 | DEV PKG - OK TO SUBMIT | 03/01/2019 | COMPLETED |
03/01/2019 | DEV PKG | 04/09/2019 | COMPLETED |
05/06/2019 | DEV PKG - RESUBMITTAL | 06/12/2019 | COMPLETED |
06/17/2019 | DEV PKG - RESUBMITTAL | 06/19/2019 | COMPLETED |
Completed Inspections
Permit Status: Complete
Permit Number: DP19-0048
Permit Description: SITE - La Suprema Co-Working.
Total Completed Inspections - 1
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/13/2020 | ENGR Engineering Final | Passed | {Activity date: 05/13/2020; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - MET WITH FRED FELIX, LANCE PETERSON(TEAMS), TOM ADKINS, AND MICHAEL OUT ON THE SITE TO DISCUSS THE ISSUES THAT WE HAVE RAISED. MR FELIX HAS MADE A DETERMINATION THAT THE RUNNING SLOPE OF THE EXISTING SIDEWALKS IS TOO STEEP TO COME FULLY INTO COMPLIANCE IN A REASONABLE MANNER. THEIR APPROVAL OF THE SITE WILL STAND AS IT IS AND THE PERMIT CAN BE CLOSED WITHOUT ANY CHANGE TO THE CONSTRUCTED CONDITIONS} ; {Activity date: 05/12/2020; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - THIS INSPECTION IS BEING APPROVED AT THIS TIME SINCE IT HAS BEEN ACCEPTED BY THE TRANSPORTATION DEPARTMENT. ALL PREVIOUSLY NOTED COMMENTS ARE ISSUES WITHIN THE RIGHTS OF WAY AND IS APPROVED WITH THE APPROVAL OF THE BUILDING OFFICIAL ON 5/12/2020.} ; {Activity date: 05/12/2020; Status: Partial Approval; Inspector: DROBERTS; Comment: Entered by RSALDAT1 - ENGINEERING FINAL IS PARTIAL AT THIS TIME AS NOTED ON THE PREVIOUS INSPECTION(SEE THE NOTES BELOW) FOR THIS SITE IN APRIL OF THIS YEAR. I AM WAITING ON A DECISION FROM C.O.T. TRANSPORTATION SINCE MY COMMENTS REFER TO WORK DONE IN THE RIGHTS OF WAY IN REGARDS TO THE NONCOMPLIANT ADA PARKING SPACE, ACCESS AISLE, AND PATHWAY INTO THE BUILDING FROM SIMPSON STREET. 4/17/2020 IS PARTIALED AT THIS TIME DUE TO THE SITE WORK IS NOT COMPLETE. THE FOLLOWING ITEMS HAVE BEEN NOTED INCORRECT DURING THIS SITE VISIT: 1) THE ADA PARKING SPACE IS NOT IN THE LOCATION THAT IS SHOWN ON THE APPROVED PLANS AND IS NONCOMPLIANT. PROVIDE US WITH APPROVED REVISED DRAWINGS FOR THIS CHANGE, OR CONSTRUCT THIS AS IT HAS BEEN APPROVED. ALSO THE RUNNING SLOPE OF THE ROADWAY WHERE THE PARKING SPACE IS TO BE CONSTRUCTED IS BETWEEN 2.6% AND 4.0%, THIS NEEDS TO BE 2% OR LESS IN ALL DIRECTIONS WHEN IT IS INSPECTED. 2) THE SIDEWALK THAT IS SHOWN IN THE AREA BETWEEN THE APPROVED PARKING SPACE AND THE ACCESS TO THE BUILDING IS NON COMPLIANT FOR THE CROSS SLOPE. CURRENTLY THE SLOPES IN THIS AREA VARY BETWEEN 2.6% TO OVER 4%, THIS WILL NEED TO BE ADDRESSED FOR THE PARKING SPACE/ACCESS AISLE TO BE COMPLIANT. ALSO AT THE DOORWAY THERE IS NOT A LANDING AT THE TOP OF THE RAMP TO ALLOW FOR A POINT OF REST WHILE OPENING THE DOOR, THE LANDING IS ON THE INSIDE OF THE DOOR. 3) THE ISSUES NOTED IN THIS AREA ARE THE RESPONSIBILITY OF THE RIGHT OF WAY DEPARTMENT FOR THE CITY OF TUCSON TRANSPORTATION DEPT. THE ACCESS RAMP LOCATED AT THE SOUTHWEST CORNER OF THIS BUILDING IS NON-COMPLIANT IN THE FOLLOWING AREAS. IT IS MISSING THE KICK PLATE ON THE RIGHT SIDE OF THE HANDRAIL GOING UP THE RAMP AND THE HANDRAIL ON THE LEFT SIDE OF THE SAME RAMP GOING UP. 4) COMPLETE THE LANDSCAPING AROUND THIS SITE PRIOR TO RECALLING THIS INSPECTION AGAIN. ALL DISTURBED AREAS WILL NEED TO HAVE SOME TYPE OF LANDSCAPING MATERIAL APPLIED EITHER PLANTS, DECOMPSED GRANITE, OR HYDROSEED PRIOR TO APPROVAL OF THE SITE. } ; {Activity date: 04/17/2020; Status: Partial Approval; Inspector: DROBERTS; Comment: Entered by DROBERT5 - IS PARTIALED AT THIS TIME DUE TO THE SITE WORK IS NOT COMPLETE. THE FOLLOWING ITEMS HAVE BEEN NOTED INCORRECT DURING THIS SITE VISIT: 1) THE ADA PARKING SPACE IS NOT IN THE LOCATION THAT IS SHOWN ON THE APPROVED PLANS AND IS NONCOMPLIANT. PROVIDE US WITH APPROVED REVISED DRAWINGS FOR THIS CHANGE, OR CONSTRUCT THIS AS IT HAS BEEN APPROVED. ALSO THE RUNNING SLOPE OF THE ROADWAY WHERE THE PARKING SPACE IS TO BE CONSTRUCTED IS BETWEEN 2.6% AND 4.0%, THIS NEEDS TO BE 2% OR LESS IN ALL DIRECTIONS WHEN IT IS INSPECTED. 2) THE SIDEWALK THAT IS SHOWN IN THE AREA BETWEEN THE APPROVED PARKING SPACE AND THE ACCESS TO THE BUILDING IS NON COMPLIANT FOR THE CROSS SLOPE. CURRENTLY THE SLOPES IN THIS AREA VARY BETWEEN 2.6% TO OVER 4%, THIS WILL NEED TO BE ADDRESSED FOR THE PARKING SPACE/ACCESS AISLE TO BE COMPLIANT. ALSO AT THE DOORWAY THERE IS NOT A LANDING AT THE TOP OF THE RAMP TO ALLOW FOR A POINT OF REST WHILE OPENING THE DOOR, THE LANDING IS ON THE INSIDE OF THE DOOR. 3) THE ISSUES NOTED IN THIS AREA ARE THE RESPONSIBILITY OF THE RIGHT OF WAY DEPARTMENT FOR THE CITY OF TUCSON TRANSPORTATION DEPT. THE ACCESS RAMP LOCATED AT THE SOUTHWEST CORNER OF THIS BUILDING IS NON-COMPLIANT IN THE FOLLOWING AREAS. IT IS MISSING THE KICK PLATE ON THE RIGHT SIDE OF THE HANDRAIL GOING UP THE RAMP AND THE HANDRAIL ON THE LEFT SIDE OF THE SAME RAMP GOING UP. 4) COMPLETE THE LANDSCAPING AROUND THIS SITE PRIOR TO RECALLING THIS INSPECTION AGAIN. ALL DISTURBED AREAS WILL NEED TO HAVE SOME TYPE OF LANDSCAPING MATERIAL APPLIED EITHER PLANTS, DECOMPSED GRANITE, OR HYDROSEED PRIOR TO APPROVAL OF THE SITE. } ; {Activity date: 04/10/2020; Status: Not ready for Inspection; Inspector: BBENEDON; Comment: Entered by RSALDAT1 - PLEASE PROVIDE CONTACT INFORMATION WHEN SCHEDULING THIS INSPECTION. INSPECTION NEEDED OF ACCESSIBLE PATH AS SHOWN ON PLAN INSIDE PROPERTY.} ; {Activity date: 12/20/2019; Status: Not ready for Inspection; Inspector: BBENEDON; Comment: Entered by SFLORES2 - Work in progress} |