Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Development Package
Address:
3001 N SWAN RD
Address NEW:
3001 N SWAN RD
Apply Date:
04/05/2017
Applicant:
Lisa Bowers
Description:
GRADING/SITE - PARKING

Permit Reviews

Permit Number - DP17-0080
Permit Status: Complete
Permit Description: GRADING/SITE - PARKING
Start Date Submittal Complete Date Status  
04/05/2017 DEV PKG - OK TO SUBMIT 04/05/2017 COMPLETED Review Details
04/05/2017 SITE and/or GRADING 05/31/2017 COMPLETED Review Details
05/31/2017 RESUB - SITE and/or GRADING 08/22/2017 COMPLETED Review Details
08/22/2017 RESUB - SITE and/or GRADING 09/11/2017 COMPLETED Review Details
09/11/2017 RESUB - SITE and/or GRADING 12/07/2017 COMPLETED Review Details

Completed Inspections

Permit Status: Complete
Permit Number: DP17-0080
Permit Description: GRADING/SITE - PARKING
Total Completed Inspections - 9
Date Description Inspector Results Comments
02/07/2018 PDSD Engineering Division Pre-Construction SITE Passed {Activity date: 02/07/2018; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - }
06/12/2018 PDSD Site/Engineering Division - Landscaping Passed {Activity date: 06/12/2018; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - }
06/12/2018 PDSD Site/Engineering Division - NPPO Passed {Activity date: 06/12/2018; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - }
06/12/2018 SITE - Stormwater Follow-up Passed {Activity date: 06/12/2018; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - } ; {Activity date: 02/22/2018; Status: Continued; Inspector: RLEDONNE; Comment: Entered by DROBERT5 - WALKED SITE WITH GC WENT OVER AP PLANS.} ; {Activity date: 03/13/2018; Status: Continued; Inspector: RLEDONNE; Comment: Entered by RLEDONN1 - }
06/12/2018 ENGR Grading Final Passed {Activity date: 06/12/2018; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - }
06/12/2018 SITE - Stormwater Final Inspection Passed {Activity date: 06/12/2018; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - }
06/12/2018 SITE - Stormwater Setup and Controls Passed {Activity date: 06/12/2018; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - }
06/12/2018 COT - ENGR - Signage Final Passed {Activity date: 06/12/2018; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - }
06/20/2018 ENGR Engineering Final Passed {Activity date: 06/20/2018; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - } ; {Activity date: 06/18/2018; Status: Partial Approval; Inspector: DROBERTS; Comment: Entered by DROBERT5 - SITE NEEDS TO BE CLEANED UP PRIOR TO CALLING IN FOR THIS FINAL INSPECTION.} ; {Activity date: 06/12/2018; Status: Partial Approval; Inspector: DROBERTS; Comment: Entered by DROBERT5 - THIS SITE IS OK FOR THE TCO WITH THE FOLLOWING ISSUES TO BE ADDRESSED.
1) THE NORTHERN ADA PARKING SPACES ON THE WEST SIDE OF THE BUILDING EXCEEDS THE MAXIMUM SLOPE VALUE IN THE LAST 2 FEET OF THE SPACE. THE CONTRACTOR HAS BEEN ADVISED TO MAKE IT COMPLIANT BEFORE REQUESTING A FINAL INSPECTION FOR THIS SITE.}

Documents

File Name Document Type  
001_COVER SHEET / NOTES_1 OF 9.TIF DEVELOPMENT PACKAGE VIEW
002_DEVELOPMENT_2 OF 9.TIF DEVELOPMENT PACKAGE VIEW
003_DETAILS_3 OF 9.TIF DEVELOPMENT PACKAGE VIEW
004_GRADING_4 OF 9.TIF DEVELOPMENT PACKAGE VIEW
005_UTILITY_5 OF 9.TIF DEVELOPMENT PACKAGE VIEW
006_LANDSCAPE_L-1.TIF DEVELOPMENT PACKAGE VIEW
007_IRRIGTION_L-2.TIF DEVELOPMENT PACKAGE VIEW
008_WATER HARVESTING_L-3.TIF DEVELOPMENT PACKAGE VIEW
009_CONSTRUCTION DETAILS_L-4.TIF DEVELOPMENT PACKAGE VIEW
None DOCUMENTS VIEW