Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TS-PRM-0324-00121

Parcel: 13608477H

Inspection Status: Not Ready

Inspection History: COT - ENGR - Sign Footing and Excavation

Date Description Inspector Results Comments
07/12/2024 COT - ENGR - Sign Footing and Excavation Not Ready insufficient clearance from reinforcing steel to earth, and wrong vertical reinforcing. #5 verts installed instead of #7. reinforcing to be welded should be A706, not A615.
07/18/2024 COT - ENGR - Sign Footing and Excavation Passed I spoke to Josh Garcia on the phone and he informed me that he instructed the contractor to put number seven bar in between the number five bars and the rings are supposed to be number three bars