Inspection History Details
Inspection Status: Not Ready
Inspection History: COT - ENGR - Sign Electrical
Permit Number - TS-PRM-0125-00039
Inspection Description - COT - ENGR - Sign Electrical
Inspection Status - Not Ready
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/20/2025 | COT - ENGR - Sign Electrical | Not Ready | Reschedule when timer and lockouts are correct. No shut off switches visible on signs. No safety lockout is provided for signs where the shut off switch is not directly visible to the sign. | |
| 07/29/2025 | COT - ENGR - Sign Electrical | Failed | A dedicated disconnect switch must be installed (if in a separate location from the sign, must be lockable). A lighting timer must be installed to shut off the signs no later than close of business or 12:00 am. Unable to locate the disconnect and timer. | |
| 09/05/2025 | COT - ENGR - Sign Electrical | Passed | Signs are installed in accordance with approved plans. |