Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Re-inspection required
Inspection History: TRSP - PIA - Engineering Final - Completion of PIA Work (Final Lot Release/Acceptance)
| Date |
Description |
Inspector |
Results |
Comments |
| 01/24/2024 |
TRSP - PIA - Engineering Final - Completion of PIA Work (Final Lot Release/Acceptance) |
|
Re-inspection required |
lees asphalt onsite to cut asphalt and pave to curb. |
| 02/07/2024 |
TRSP - PIA - Engineering Final - Completion of PIA Work (Final Lot Release/Acceptance) |
|
Re-inspection required |
brass survey locator for sewer patch rejected. collar for fiber rejected. |
| 02/09/2024 |
TRSP - PIA - Engineering Final - Completion of PIA Work (Final Lot Release/Acceptance) |
|
Partial Pass |
punch list uploaded. site passes with partial inspection. |
| 02/22/2024 |
TRSP - PIA - Engineering Final - Completion of PIA Work (Final Lot Release/Acceptance) |
|
Partial Pass |
survey monument needs placement in concrete. |
| 02/26/2024 |
TRSP - PIA - Engineering Final - Completion of PIA Work (Final Lot Release/Acceptance) |
|
Passed |
all punch list items completed and site passes final inspection. |