Inspection Status: Re-inspection required

Inspection History: TRSP - ROW - Concrete - Subgrade/Forms (Pre-Pour)

Date Description Inspector Results Comments
11/05/2026 TRSP - ROW - Concrete - Subgrade/Forms (Pre-Pour) Re-inspection required The site is overly saturated with water with visible footprints in the mud, needs to be re-compacted, no expansion material on site, and no difference in depth between sidewalk and driveway. Sidewalk should be a minimum of 4 inches thick and driveway shall be a minimum of 6 inches thick.
11/06/2026 TRSP - ROW - Concrete - Subgrade/Forms (Pre-Pour) Passed Site is ready for concrete