Inspection History Details
Inspection Status: Re-inspection required
Inspection History: TRSP - ROW - Concrete - Acceptance (Post-Pour)
Permit Number - TR-ANN-1024-00607
Inspection Description - TRSP - ROW - Concrete - Acceptance (Post-Pour)
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/03/2025 | TRSP - ROW - Concrete - Acceptance (Post-Pour) | Re-inspection required | 2 panels in driveway to fix, clean off tire marks | |
01/27/2025 | TRSP - ROW - Concrete - Acceptance (Post-Pour) | Not Ready | replacement pour just finished, will need to be rescheduled once cured, joints are scored, and forms are pulled. | |
01/28/2025 | TRSP - ROW - Concrete - Acceptance (Post-Pour) | Passed | out of spec sidewalk panels removed and replaced, grades and joints checked and approved |