Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: TRSP - ROW - Concrete - Subgrade/Forms (Pre-Pour)
Permit Number - TR-ANN-1024-00595
Inspection Description - TRSP - ROW - Concrete - Subgrade/Forms (Pre-Pour)
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/15/2024 | TRSP - ROW - Concrete - Subgrade/Forms (Pre-Pour) | Re-inspection required | please reprocess areas of subgrade with rock segregation for a more even base | |
11/18/2024 | TRSP - ROW - Concrete - Subgrade/Forms (Pre-Pour) | Re-inspection required | Rock segregation has been resolved, but subgrade still has areas that are too loose please re-compact | |
11/19/2024 | TRSP - ROW - Concrete - Subgrade/Forms (Pre-Pour) | Passed | Subgrade and forms checked and approved, please repair cracked corner of sidewalk |