Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: TRSP - ROW - Concrete - Subgrade/Forms (Pre-Pour)

Permit Number - TR-ANN-0824-00468

Inspection Description - TRSP - ROW - Concrete - Subgrade/Forms (Pre-Pour)

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
09/19/2024 TRSP - ROW - Concrete - Subgrade/Forms (Pre-Pour) Re-inspection required subgrade of sidewalk too muddy, stake caps needed, form where new meets existing needs to be removed and replaced with a 4” expansion joint, 6” joints needed behind curb and driveway apron
09/20/2024 TRSP - ROW - Concrete - Subgrade/Forms (Pre-Pour) Passed Still needs expansion joints, 6 inch at driveway apron and 4 inch at end of sidewalk. Otherwise passed and ready for pour