09/19/2024 | TRSP - ROW - Concrete - Subgrade/Forms (Pre-Pour) | Re-inspection required | subgrade of sidewalk too muddy, stake caps needed, form where new meets existing needs to be removed and replaced with a 4” expansion joint, 6” joints needed behind curb and driveway apron | |
09/20/2024 | TRSP - ROW - Concrete - Subgrade/Forms (Pre-Pour) | Passed | Still needs expansion joints, 6 inch at driveway apron and 4 inch at end of sidewalk. Otherwise passed and ready for pour |