Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 12809006B


Addresses:

1104 S CRAYCROFT RD


Inspection Status: Partial Pass

Inspection History

Permit Number - TD-DEV-1124-00308

Inspection Description -

Inspection Status - Partial Pass

Date Description Inspector Results Comments
07/28/2025 Partial Pass Curb forms are accurate to plan set, okay to pour.
Trash enclosure bollards are placed properly and to the necessary depth, okay to pour.
07/30/2025 Partial Pass Sidewalk layout for main entrance was discussed, there will be a curb ramp the length of the opening leading up to the front of the building, slopes will be maintained at less than 8.3% for the ramps and less then 2% everywhere else to avoid cross slope conflicts. Ramps will need truncated domes or saw cuts as a form of detectable warning. Delete two curbs from the plans that were interfering with pedestrian access.
08/05/2025 Partial Pass Retaining wall at rear of building: footing size and reinforcement is good on the West half of the wall.
08/06/2025 Partial Pass Retaining wall along North of building: size, depth, and reinforcement is correct. Okay to pour footing for all sections where rebar is installed.
08/15/2025 Partial Pass Sub-grade is good. Forms are correct, okay to pour V-ditch in Northern most drive path.
08/21/2025 Partial Pass Remaining section of retaining wall has been poured and curbing at West end of building D is complete per plans. Sub-grade is ready for valley gutter to be formed on West side of project.