Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: TD-DEV-1124-00308

Parcel: 12809006B


Addresses:

1104 S CRAYCROFT RD

Inspection Status: Partial Pass

Inspection History: ENGR Paving

Date Description Inspector Results Comments
09/05/2025 ENGR Paving Partial Pass Sub-grade is being prepped, compaction results are pending, will need additional inspection to monitor progress prior to AB placement.
09/08/2025 ENGR Paving Partial Pass Sub-grade is at proper elevation and compaction, okay to place AB.
09/09/2025 ENGR Paving Partial Pass AB is being worked on West side, progress is slow; not ready to pave, still need to get elevations and compaction
09/10/2025 ENGR Paving Not Ready AB along West side: 3" depth for AC is not present everywhere, loose AB in some areas. Not ready for asphalt.
09/11/2025 ENGR Paving Partial Pass AB placement, West and North of concrete valley gutter: compaction, depth, and slope are correct, ready for AC.
09/12/2025 ENGR Paving Partial Pass Paving progress in Northern most driveline is good.
AB along west driveline, east of V-ditch, for the length of the main building: depth and thickness is good, okay for AC pending compaction testing results.
09/15/2025 ENGR Paving Partial Pass Paving on the West side progress: 3rd party testing is on site. Slopes, thickness, finish elevations, and compaction are all good.
09/16/2025 ENGR Paving Partial Pass AB placement, North of main building, remainder: Compaction and elevations are good; okay to pave both sides of building D to the valley gutter on the east side.
09/17/2025 ENGR Paving Partial Pass AB placement: Elevations, slopes, thickness, and compaction are good, okay to pave along north side of main building and from new metal buildings East to the existing pavement, creating a straight line perpendicular to the main building
09/18/2025 ENGR Paving Partial Pass Paving North of main building, from metal buildings to existing pavement, 3rd party tester is on site and taking samples. Paving progress is good.
09/22/2025 ENGR Paving Partial Pass Final portion at NE of site, AB depth, elevation, and compaction are good, okay to pave balance of site.
09/23/2025 ENGR Paving Partial Pass Final section of paving, NE portion of site: Thickness is good, slopes are good, 3rd party tester is onsite, density is good.