Permit Number - TD-DEV-1122-00044

Inspection Description -

Inspection Status - Not Ready

Date Description Inspector Results Comments
09/30/2025 Not Ready 9/30/25
Curb form depth is not correct to PAG 209 detail. Fix forms per the detail and request inspection when ready before pouring.
10/02/2025 Partial Pass 10/2/25
Curbs poured on both sides of drive through to north of building and over to Longfellow. Modified curb to south of building also being poured. In progress
10/20/2025 Partial Pass Areas inspected today: (Adjacent to refuse enclosure North side, excluding curb ramp)(curb ramp at SE corner of building)(extension into North parking including curb ramp) : forms are set properly; sub-grade, slopes, and dimensions are correct. Ensure expansion joints are placed adjacent to other structures. Okay to pour.