Inspection Status: Not Ready

Inspection History: For trash and recycling enclosures

Permit Number - TD-DEV-1122-00021

Inspection Description - For trash and recycling enclosures

Inspection Status - Not Ready

Date Description Inspector Results Comments
05/14/2025 For trash and recycling enclosures Not Ready 05/14/25, Footing and bollards were completed without inspections being done. Either GPR now needs to be completed or engineer on record will have to certify proper placement of both. Enclosure adjacent to building bollards need to have 10' of separation between them, these are at 8'-9". Again this enclosure was completed at footing and bollards with no inspections.
05/15/2025 For trash and recycling enclosures Partial Pass 05/15/25, enclosure to the outside of lot can be grouted on the first lift.
05/23/2025 For trash and recycling enclosures Not Ready Nothing is completed, walls, grout, gates etc.
05/23/2025 For trash and recycling enclosures Not Ready Nothing is completed, walls, grout, gates etc.
06/06/2025 For trash and recycling enclosures Partial Pass 06/-6/25, Bollards are 2'-6" below grade but are set 10'-6" apart rather than the 10' required. Set form to out side of wall is 1'-6" should be 1'-8". Slab rebar looks good. Pour everything as is.
06/25/2025 For trash and recycling enclosures Partial Pass additional vertical support at front enclosure added to meet COT standards. Okay to grout to 4ft on both enclosures.
06/26/2025 For trash and recycling enclosures Passed Vertical reinforcement and bond beam are good, okay to grout to top on both enclosures.
07/30/2025 For trash and recycling enclosures Passed Floors and aprons complete.