Inspection History Details
Inspection Status: Partial Pass
Inspection History: ENGR - Drainage Structures
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/15/2024 | ENGR - Drainage Structures | Partial Pass | viewed (6) 5’x5’x 1’-6” column footers with (4) #6 bars each way top and bottom and all anchor bolt bracing templates are in place. (OK to pour) |