Permit: TD-DEV-0924-00266

Parcel: 12105012H


Addresses:

5502 E GRANT RD

Inspection Status: Partial Pass

Inspection History: For trash and recycling enclosures

Date Description Inspector Results Comments
11/05/2026 For trash and recycling enclosures Partial Pass OK to pour footer then build wall.. contractor wants to grout wall in one lift. This is OK with weep holes at bottom course with pictures of grout through the holes. Or we will have to observe grout/vibrating. Schedule pre grout inspection prior to grouting to check bond beam.
11/13/2026 For trash and recycling enclosures Partial Pass Okay to grout walls of RE to top. Schedule inspection prior to pouring bollards and floor rebar mat