Parcel: 12509012A


Addresses:

2540 E 10TH ST


Inspection Status: Passed

Inspection History: ENGR Engineering Final

Permit Number - TD-DEV-0423-00202

Inspection Description - ENGR Engineering Final

Inspection Status - Passed

Date Description Inspector Results Comments
08/29/2024 ENGR Engineering Final Passed Ready for CO

SECTION307
HANDRAILS AND GUARDRAILS
307.1General.
Every exterior and interior flight of stairs having more than four risers shall have a handrail on one side of the stair and every open portion of a stair, landing, balcony, porch, deck, ramp or other walking surface that is more than 30 inches (762 mm) above the floor or grade below shall have guards. Handrails shall be not less than 30 inches (762 mm) in height or more than 42 inches (1067 mm) in height measured vertically above the nosing of the tread or above the finished floor of the landing or walking surfaces. Guards shall be not less than 30 inches (762 mm) in height above the floor of the landing, balcony, porch, deck, or ramp or other walking surface.