Inspection Status: Not Ready

Inspection History: ENGR Paving

Date Description Inspector Results Comments
02/10/2025 ENGR Paving Not Ready Still in progress. 7 am revisit on 02/11/25 to pull, string line. Make sure compaction test is set up for disturbed areas.
02/11/2025 ENGR Paving Passed All sub grade issues have been repaired, string was set and mumps in grade were removed to create a proper flow line in the valley drain of the asphalt. Compaction results meet and or exceeds requirements needed. Dumpster enclosure is still an issue due to the overhead power line being directly over it. Contractor is at risk due to this issue.