Inspection History Details
Inspection Status: Partial Pass
Inspection History: ENGR Paving
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/03/2026 | ENGR Paving | Partial Pass | 9/3/26 Main entryway driveway from golf links to parking lot subgrade compacted. I measured the depths with string line and it needed some adjustment contractor will send pictures of Subgrade finished and cleaned up and recompacted before placing AB..OK to place AB pending pictures. |
|
| 09/08/2026 | ENGR Paving | Not Ready | AB is not consistent enough for paving. There areas over 1" and many +.5" from 4". When AB is within a half inch, it will be ready. |